Missing User info in RLRQ APDU.

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Ondrej_Pokorny , 9 August, 2022
Forums
DLMSDirector

Hello Mikko,
our DLMS library discards response to RLRQ (Association release, i.e. Disconnect in Director) because of missing User info.
I have discussed that with our library provider:
"
The user information field is mandatory in RLRQ on ciphered association.
The user information field shall match that of AARQ (Deciphered values shall match).
I have included the snapshot from the green book. (see picture attached).
"
Could You add User info in RLRQ?

Best Regards
Ondrej

Image
Profile picture for user Kurumi

Kurumi

3 years 10 months ago

Hi Ondrej,

Hi Ondrej,

There are some older meters that can't handle the user information field in RLRQ even though those meters are using ciphered connections. For that reason, you need to select "Use protected release" from the "Advanced" tab and user information is sent in the RLRQ.

BR,
Mikko

Ondrej_Pokorny

3 years 10 months ago

Hello Mikko,

Hello Mikko,
I confirm that. Disconnecting works OK now.
Thank You.

Best Regards
Ondrej

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin