By ragavan , 19 May, 2022
Forums
General discussion

Dear Mikko,

could find imageUpdate function in c library. with what parameters this has to be invoked?
int imageUpdate(connection* connection, char* identification, uint16_t identificationSize, unsigned char* image, uint32_t imageSize)

connection - connection object
identification - ?
identificationSize - ?
image - assume that its binary image base pointer
imageSize - image size

what are identification and identificationSize parameters? from where to get those?
what is the purpose of those?

Regards
Ragavan IPS

ragavan

4 years 5 months ago

Hi Sir,

Hi Sir,

please give clarification of the function?

Thanks
Ragvan IPS

Profile picture for user Kurumi

Kurumi

4 years 5 months ago

Hi,

Hi,

identification: Image identification string that is received from the meter manufacturer.
identificationSize: length of identification.

identification is the firmware identifier name that is saved for the meter. Some meter manufacturers define the format and it will fail if the format is not correct.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101
  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202

New forum topics

  • Association refresh related issue
  • Need RJ45 pin configuration for Saral 300 and Saral 305 Secure meters
  • Query Regarding Class 63 Status Mapping Support in Gurux DLMS Python
  • Inhemeter
  • DLMS Server - Profile Generic - can't add too many items to profile generic capture object - how to set maximum profile entries
More

Who's new

  • Eric@li
  • Asier Sierra
  • BlessyAnn
  • sravya.thota@m…
  • Diwakar
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin