Big increased CPU load when going from HLS5 to HLS7

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By AndreasAtPowel , 27 January, 2022
Forums
Gurux.DLMS

Hi
You have earlier had contact with Christer during development of suite1 for Sanxing meters. We have now deployed some of what we have done and see a big increase in CPU load on the machines. Could there be any issues in Gurux regarding this or do you think this is as expected?

I attach some screenshots of CPU load when running in suite0 and suite1(HLS7)

Image
Profile picture for user Kurumi

Kurumi

4 years 6 months ago

Hi,

Hi,

Sorry to say, but this is expected. HLS7 is more complicated than HLS5. I have read a lot for ECDSA and I have a few ideas that might help to decrease CPU usage. I'll send more information after I have received answers to my questions and verified that those ideas can be used for this.

BR,
Mikko

AndreasAtPowel

4 years 6 months ago

It's really bad now.

It's really bad now.

Image
Profile picture for user Kurumi

Kurumi

4 years 6 months ago

Hi,

Hi,

I'll check this and get back to you later today.

BR,
Mikko

AndreasAtPowel

4 years 6 months ago

This is probably something

This is probably something you already know, but in case it can help. I ran a collection of values through a profiler and the "bad boy" seem to be GXDLM.ReceiverReady

Image
Profile picture for user Kurumi

Kurumi

4 years 6 months ago

Hi,

Hi,

This is a different scenario than I expected. Can you get the hex trace from the sent and received bytes and send it to me by email?

BR,
Mikko

AndreasAtPowel

4 years 6 months ago

Hi Has sent you a log.

Hi
Has sent you a log.

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More

Who's new

  • BaEdhlfwwvUqFMkOYk
  • CrzONrPdvkWUif…
  • kra4026
  • HilipLot
  • NithnCXPiBJHVG…
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin