By ikhwan_fn , 8 July, 2021
Forums
DLMSDirector

anyone can describe this info to gurux dlms director?

Image

ikhwan_fn

4 years 11 months ago

i try to debug and these are

i try to debug and these are the result
19:49:37
<HDLC len="9" >
<TargetAddress Value="1" />
<SourceAddress Value="35" />
<FrameType Value="53" />
<DisconnectRequest>
</DisconnectRequest>
</HDLC>

Profile picture for user Kurumi

Kurumi

4 years 11 months ago

Hi,

Hi,

Try to change the device address to 0x10. Now it's 1. Set client address to 0x10.

BR,
Mikko

ikhwan_fn

4 years 11 months ago

how about this?

how about this?
16:15:34
<HDLC len="A" >
<TargetAddress Value="A3" />
<SourceAddress Value="4" />
<FrameType Value="93" />
<Snrm>
</Snrm>
</HDLC>

16:15:35
<HDLC len="20" >
<TargetAddress Value="4" />
<SourceAddress Value="A3" />
<FrameType Value="73" />
<PDU>
<Ua>
<MaxInfoTX Value="352" />
<MaxInfoRX Value="352" />
<WindowSizeTX Value="1" />
<WindowSizeRX Value="1" />
</Ua>
</PDU>
</HDLC>

16:15:35
<HDLC len="2B" >
<TargetAddress Value="A3" />
<SourceAddress Value="4" />
<FrameType Value="10" />
<PDU>
<AssociationRequest>
<ApplicationContextName Value="LN" />
<InitiateRequest>
<ProposedDlmsVersionNumber Value="06" />
<ProposedConformance>
<ConformanceBit Name="BlockTransferWithGetOrRead" />
<ConformanceBit Name="BlockTransferWithSetOrWrite" />
<ConformanceBit Name="BlockTransferWithAction" />
<ConformanceBit Name="MultipleReferences" />
<ConformanceBit Name="Access" />
<ConformanceBit Name="Get" />
<ConformanceBit Name="Set" />
<ConformanceBit Name="SelectiveAccess" />
<ConformanceBit Name="Action" />
</ProposedConformance>
<ProposedMaxPduSize Value="FFFF" />
</InitiateRequest>
</AssociationRequest>
</PDU>
</HDLC>

16:15:36
<HDLC len="48" >
<TargetAddress Value="4" />
<SourceAddress Value="A3" />
<FrameType Value="30" />
<PDU>
Invalid tag.

16:15:37
<HDLC len="20" >
<TargetAddress Value="4" />
<SourceAddress Value="A3" />
<FrameType Value="73" />
<PDU>
<Ua>
<MaxInfoTX Value="352" />
<MaxInfoRX Value="352" />
<WindowSizeTX Value="1" />
<WindowSizeRX Value="1" />
</Ua>
</PDU>
</HDLC>

Profile picture for user Kurumi

Kurumi

4 years 11 months ago

Hi,

Hi,

I need a meter reply in hex format. I can't see what is the problem.

BR,
Mikko

ikhwan_fn

4 years 11 months ago

now can connect using optical

now can connect using optical probe. but i want connect using rs232

Profile picture for user Kurumi

Kurumi

4 years 11 months ago

Hi,

Hi,

Read local port settings ad check what device address should be for RS-232.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin