By velane23 , 19 September, 2020
Forums
General discussion

Hi Mikko,
I tested arduino Client app and is able to connect with the meter. I simulated with UCS demo meter and connected the arduino. The connection get disconnected with message that operation not possible. The message is highlighted below:
RECEIVED:
<AssociationRequest>
<ApplicationContextName Value="LN" />
<InitiateRequest>
<ProposedDlmsVersionNumber Value="06" />
<ProposedConformance>
<ConformanceBit Name="Action" />
<ConformanceBit Name="SelectiveAccess" />
<ConformanceBit Name="Set" />
<ConformanceBit Name="Get" />
<ConformanceBit Name="MultipleReferences" />
<ConformanceBit Name="BlockTransferWithAction" />
<ConformanceBit Name="BlockTransferWithSetOrWrite" />
<ConformanceBit Name="BlockTransferWithGetOrRead" />
</ProposedConformance>
<ProposedMaxPduSize Value="FFFF" />
</InitiateRequest>
</AssociationRequest>
1'36.190 *** CurrentLNAssociationObject object-list completed
1'36.206 Max.Pdu size = 256
SENT:
<AssociationResponse>
<ApplicationContextName Value="LN" />
<AssociationResult Value="00" />
<ResultSourceDiagnostic>
<ACSEServiceUser Value="00" />
</ResultSourceDiagnostic>
<MechanismName Value="NO_SECURITY" />
<InitiateResponse>
<NegotiatedDlmsVersionNumber Value="06" />
<NegotiatedConformance>
<ConformanceBit Name="Action" />
<ConformanceBit Name="SelectiveAccess" />
<ConformanceBit Name="Set" />
<ConformanceBit Name="Get" />
<ConformanceBit Name="MultipleReferences" />
<ConformanceBit Name="BlockTransferWithSetOrWrite" />
<ConformanceBit Name="BlockTransferWithGetOrRead" />
</NegotiatedConformance>
<NegotiatedMaxPduSize Value="0100" />
<VaaName Value="0007" />
</InitiateResponse>
</AssociationResponse>
RECEIVED:
<AssociationRequest>
<ApplicationContextName Value="LN" />
<InitiateRequest>
<ProposedDlmsVersionNumber Value="06" />
<ProposedConformance>
<ConformanceBit Name="Action" />
<ConformanceBit Name="SelectiveAccess" />
<ConformanceBit Name="Set" />
<ConformanceBit Name="Get" />
<ConformanceBit Name="MultipleReferences" />
<ConformanceBit Name="BlockTransferWithAction" />
<ConformanceBit Name="BlockTransferWithSetOrWrite" />
<ConformanceBit Name="BlockTransferWithGetOrRead" />
</ProposedConformance>
<ProposedMaxPduSize Value="0100" />
</InitiateRequest>
</AssociationRequest>
1'36.596 *** AARQ received in Associated state
SENT:
<ExceptionResponse>
<StateError Value="ServiceNotAllowed" />
<ServiceError Value="OperationNotPossible" />
</ExceptionResponse>
1'36.798 *** Disconnected
1'36.830 *** EXCEPTION *** HDLC Disconnected
1'37.547 *** EXCEPTION *** Operation aborted
1'37.719 Port 10 closed
1'38.717 STOPPED after 01m 38s

Kindly let me know how in which file, the objects to be read are to be modified.

Further, I tried to compile the Arduino server and I got the following error message:
variable or field 'time_now' declared void

Please help me to correct the error. Also inform me how to simulate values in server.

Regards,
D.Taniguevelane

Profile picture for user Kurumi

Kurumi

5 years 12 months ago

Hi,

Hi,

The client example was calling com_initializeConnection twice. This is now fixed. Get the latest version.

What board you are using? We can't get this time_now error. I don't know how to simulate UCS values. I haven't used that simulator.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)