Hii Mikko,
I want to know meter type of the DLMS meter using OBIS code. In India, it seems that obis code for meter type is 0.0.94.91.0.255 so, when I tried to read two different types of meters (Secure premier 300 3P-4W and Genus single phase) on gurux director, meter type value for 3P-4W is 3 and for single phase meter is 5. For my application, I need to know the meter type beforehand, so while reading meter parameters, I can send OBIS code accordingly. May I know what are the different values for meter types using above OBIS code. IN, IS15959 , it is given that for 3P-3W value will be 0 and 3P-4W value will be 1 for meter type. But for 3P-4W secure preimer 300, I get meter type value as 3. I am confused about this.
Please let me know about this issue.

Regards,
Omkar

Profile picture for user Kurumi

Kurumi

6 years 3 months ago

Hi Omkar,

Hi Omkar,

0.0.94.91.0.255 is Cumulative Tamper Count. Meter Type is 0.0.94.91.9.255.
0 indicates 3P-3W and 1 indicates 3P-4W

BR,
Mikko

iomkar

6 years 3 months ago

Hi Mikko,

Hi Mikko,
It was mistake from my side that I mentioned 0.0.94.91.0.255. Actually I tried reading 0.0.94.91.9.255, but it gave me value 3 as a meter type. Also, what values can be expected for single phase DLMS meter?

Regards,
Omkar

Profile picture for user Kurumi

Kurumi

6 years 3 months ago

Hi Omkar,

Hi Omkar,

You need to ask this from the meter vendor. As fas as I know only values 1 and 2 are used.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
  • dw772
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin