Hi,

I am trying to read out the parameters of a Landis & Gyr CU-P40 modem. According to Landis the correct logical address should be 17, but everytime I get the full parameters of the meter meter instead.

Profile picture for user Kurumi

Kurumi

6 years 5 months ago

Hi,

Hi,

You need to change "Logical server address" for Landis + Gyr. This is L+G specific way to handle external connection parameters.

Open GXDLMSDirector and change "Logical server address" from zero to 1. Make a connection and read the association view again.

BR,
Mikko

rheijser

6 years 5 months ago

I have used logical server

I have used logical server addres 1, see screenshot (P40). After collection objects the objects in screenshot P40_results are available. For example at register the objects U1, U2, U3, L1, L2 and L3 are shown which tells me the meter objects haven been collected.

Image
Profile picture for user Kurumi

Kurumi

6 years 5 months ago

Hi,

Hi,

Your physical address is the serial number. Change it to 1. Change also the "Address Type" from SerialNumber to Default.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • Anaglyfos Trading CC
  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin