  3. How To Decoding This Response Data From Meter

How to decoding this response data from meter

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By esmailsoror , 7 January, 2020
Forums
General discussion

HI
I have to two Type of meter
How can in decoding the response of meter
==============
BaudRate set to : 4800,1n8

>>/BBS?!
<</SLFZ\WMSG989045264
>>ACK
30010080C1600000080A000000000007EOT790A
012315020505029213130072003D0800EOT228E
219AA38B9C71F08A00000000A504309CEOTE6E3
735E8A00000000000002E49C735E8A00EOTF6EF
040549808B000000000000000405495EEOT2271
8B04309C735E8A00000000000002249CEOTC9EF

how to get cons and date and time from those data
==============
>>/?!
<<EAA5EAA kWh Meter
>>ACK051
<< P0 (71) f
>>P1(0000)
<<ACK
>> R1 00(10) b
<< 00(00702998400000000000450B5F)
>> R3 05(10) e
<<05(00201D590060907C0040D19800000000000000000000000000C08F5E202851CD402024B6302A11C1000000000000000000000000402024B6A053DD2143658709) u

Profile picture for user Kurumi

Kurumi

6 years 5 months ago

Hi,

Hi,

First one looks odd. I don't know what standard that is.

Second meter is using IEC 62056-21 and not DLMS. It's using Mode C and you need to know address where to read data from the meter.

P0 i seed that meter sends and P1 is generated hash that the client sends to the meter.
This is the password. You can read more from:

http://gurux.fi/node/5415

BR,
Mikko

esmailsoror

6 years 5 months ago

In reply to Hi, by Kurumi

P0 and P1 in this Meesage is

P0 and P1 in this Meesage is example .but i have not problem with password .i get ack from the meter and get data aftaer send password.
i have this problem :
>> R1 00(10) b
<< 00(00702998400000000000450B5F)
==R100(10)b is command for get serial of meter and response is 00(00702998400000000000450B5F).
== how to get serail from 00(00702998400000000000450B5F)
(serail is 7928904)

esmailsoror

6 years 5 months ago

>> R3 05(10) e is command for

>> R3 05(10) e is command for get active cons that meter response is 05(00201D590060907C0040D19800000000000000000000000000C08F5E202851CD402024B6302A11C1000000000000000000000000402024B6A053DD2143658709) u
=====
how can i get active cons from this response

thanks esmailsoror

Profile picture for user Kurumi

Kurumi

6 years 5 months ago

Hi,

Hi,

Problem with IEC 62056-21is that the content of the data is not described on the standard.
Different manufacturers have different ways to communicate with the meter.
You need to ask for this information from the manufacturer.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin