How to read Elgama 300 G3A.144 using IEC with serial number

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By wseang , 8 November, 2019
Forums
DLMSDirector

I have an Elgama 300 G3A.144 meter, and i try to use GXDLMSDirector to read the serial number start with 0 using start protocol IEC, however the GXDLMSDirector will auto remove the first 0, could you please advise how to enter the S/N with starting 0 ?

Profile picture for user Kurumi

Kurumi

6 years 10 months ago

Hi,

Hi,

Even leading zero is removed from the UI, it's used when the server address is counted.

BR,
Mikko

wseang

6 years 10 months ago

Sorry, I am not understand

Sorry, I am not understand what mean by server address is counted.

Do you mean that if we would like to maintain the serial number started with zero, we need to disable the server address ?

If yes, then how I am disable or do not count for server address ?

This is because my meter require the full serial number started with zero in IEC protocol. Please help & Thanks.

Profile picture for user Kurumi

Kurumi

6 years 10 months ago

Hi,

Hi,

So you are using an optical probe. We'll modify this, so leading zero is added for IEC.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • Anaglyfos Trading CC
  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin