Hi,

I have used Gurux GXDLMSDirection version 8.1.1807. My meter used Texas Instrument DLMS library. When I connected to my meter with gurux director in lowest authentication (no authentication), we got 4 objects. We can read 3 other objects, but when I read clock object, I got error message Insufficient Memory
Why this problem can happen ? Can you guide us how to solve this problem?

Thank you.

Image
Profile picture for user Kurumi

Kurumi

7 years 9 months ago

Gurux GXDLMSDirection version 8.1.1807 Insufficient Memory probl

Hi,

Can you send a log to the forum. Just reading the clock messages is enough.

BR,

Mikko

Buddy

7 years 8 months ago

The clock messages of Gurux GXDLMSDirection version 8.1.1807

Dear Mikko,

Thanks a lot for your reply.
Here is the clock messages as you requested :
18/09/2018 11:02:04Read object type Clock index: 2
<- 11:02:04 7E A0 19 03 21 32 6F D8 E6 E6 00 C0 01 C1 00 08 00 00 01 00 00 FF 02 00 60 1A 7E
18/09/2018 11:02:04-> 11:02:04 7E A0 1D 21 03 52 85 6F E6 E7 00 C4 01 C1 00 09 07 D0 01 01 06 00 14 13 FF 01 A4 00 70 93 7E

Regards
Buddy

Profile picture for user Kurumi

Kurumi

7 years 8 months ago

Gurux GXDLMSDirection version 8.1.1807 Insufficient Memory

Dear Buddy,

Thanks to this. Date time value is D0010106001413. There are 9 bytes and there should be 12.
So date and time are not correct. First two bytes should be the year and this is not correct.
Your lib or meter is returning wrong data for some reason.

BR,

Mikko

Buddy

7 years 8 months ago

In reply to Gurux GXDLMSDirection version 8.1.1807 Insufficient Memory by Kurumi

Dear Mikko,

Dear Mikko,

Thanks a lot for your analysis.
We have corrected the data from the meter, and we have no more Insufficient Memory issue now.

Best Regards

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin