By coolex , 18 October, 2016
Forums
Gurux.DLMS

Hi,
can you please help me, what I am making wrong?
When I add device with manufacture ACE device communicate (but say wrong manufacture ID ZPA not ACE).
When I create new manufacture ZPA with same setting like ACE, device communication timeout.
I think problem is in save setting of serial port, because every time when i reopen device properties, i must set serial port again.

For ZPA electro meters use:
Manufacture ID: ZPA
Start protocol: IEC
Authentification: Low
Password: last 6 numbers of serial number
Baud Rate: 300
Data bit: 7
Parity: Even
Stop Bits: One

My OS: Windows 7 + USB/RS485 converter

Regards,
Jakub

Profile picture for user Kurumi

Kurumi

9 years 7 months ago

ZPA electro meter

Hi,

When you start communicating with the meter you use IEC at first.
In IEC you get wrong manufacturer error.

When you create new template you can pass this phase, but meter is not returning anything in DLMS handshake. Reason is that your client or server address is not correct.

Can you ask what client and server address you should use from the manufacturer?

BR,

Mikko

coolex

9 years 7 months ago

Pictures say more than words

I have default manufacture values, just change:
Protocol: DLMS => IEC
Authentification: None => Low
Password: 6digits

When I use manufacture actaris electricity:
https://s22.postimg.org/9y7q64hg1/actaris_1_create.png
communication works:
https://s22.postimg.org/99yvn6iq9/actaris_2_connect.png
and when open edit settings remember OK

But when I create new manufacture (ZPA)
https://s22.postimg.org/42dsiq24x/zpa_1_create.png
everything looks OK, same configuration, but connection timeout
https://s22.postimg.org/xvksrbqs1/zpa_2_connect.png
I think so, problem is in remember values of serial port settings, because when reopen edit window, it have wrong values:
https://s22.postimg.org/mki52yjwx/zpa_3_edit.png

And next problem is when I save project, it's look OK, but when I try it open it write error:
https://s22.postimg.org/oy02tyyc1/gxldms_open_project.png

With regards,
Jakub

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin