By ale282 , 13 July, 2015

Hi Mikko,

we should retrieve data from a Kamstrup Omnipower 3phase smart meter. We asked to Kamstrup some descriptions about their DLMS implementation and we obtained this information for the low level access (to read electrical runtime values and load profiles)

Primary Module interface Association with Low Level security (Password protected)
- Client SAP: 18
- Server SAP: 16
- Context name: Logical name addressing
- Mechanism name: Low Level security. Password default is ‘12345’
- Conformance: GET, Block transfer with GET, SET, ACTION, SELECTIVE ACCESS

Optical interface Association with Low Level security (Password protected)
- Client SAP: 19 1
- Server SAP: 16
- Context name: Logical name addressing
- Mechanism name: Low Level security. Password default is ‘12345’
- Conformance: GET, Block transfer with GET, SET, ACTION, SELECTIVE ACCESS
Association used from Module_Port_2 interface:
CCC Module interface Association with Low Level security (Password protected):
- Client SAP: 20 2
- Server SAP: 16
- Context name: Logical name addressing
- Mechanism name: Low Level security. Password default is ‘12345’
- Conformance: GET, Block transfer with GET, SET, ACTION, SELECTIVE ACCESS

We succeed reading public values with the configuration that you suggest (client 16 server 1 no password) but with the settings suggested by Kamstrup it's impossible to connect to the meter. This is the DLMSDirector log (version 7.0.47.1).

Log created 10:20:41
10:20:51 Initializing Network connection.
10:20:52 Send SNRM request.
7E A0 20 01 25 93 A5 0B 81 80 14 05 02 00 80 06 02 00 80 07 04 00 00 00 01 08 04 00 00 00 01 CE 6A 7E
10:20:57 Failed to receive reply from the device in given time.

Have you experience with this smart meter?
Thank you
BR

Alessio

Profile picture for user Kurumi

Kurumi

10 years 12 months ago

Kamstrup Omnipower 3Phs

Hi,

Check your settings. It seems that Client and server IDs are wrong. In trace your values are following:

Server ID: 0x0
Client ID: 0x49

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Possible memory leak in file dlms.c, getCompactArrayItem(), getCompactArrayItem2()
  • Official Gurux.DLMS.Client.Example.Net fails during High GMAC secure association (Invalid PDU), while Gurux Director connects successfully
  • gurux_dlms.GXDateTime.GXDateTime object Error in Python
  • T_APPL_DATA_LN_N1 subtest 3 fails on an LN-only server regardless of the response to a non-existing-object GET
  • Version mismatch between Gurux.DLMS 9.x and Gurux.Common/Gurux.Serial 8.x
More

Who's new

  • sheldon_ariola
  • DtkfMfCBWyhwcO…
  • CRISTIAN MAXENTI
  • mPDxPIQgXwPXoV…
  • AaronAcecy
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin