Hi,
I am trying to generate xml file for my Linyang meter but I am getting error as below.
C:\Users\Test\Desktop\gurutry3\Gurux.DLMS.Net-master\Gurux.DLMS.Net-master\Gurux.DLMS.Simulator.Net\bin\Debug\netcoreapp3.1>dotnet Gurux.DLMS.Simulator.Net.dll -h 172.17.1.171 -p 4059 -i WRAPPER -o results.xml -t Verbose
Standard: DLMS
Send AARQ request
TX: 3:09:45 PM 00 01 00 10 00 01 00 1F 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 62 1E 5D FF FF
RX: 3:09:45 PM 00 01 00 01 00 10 00 2B 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 20 18 1D 04 00 00 07
Parsing AARE reply61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 20 18 1D 04 00 00 07
Parsing AARE reply succeeded.
TX: 3:09:45 PM 00 01 00 10 00 01 00 0D C0 01 C1 00 0F 00 00 28 00 00 FF 02 00
RX: 3:09:45 PM 00 01 00 01 00 10 00 05 C4 01 C1 01 0B
Disconnecting from the meter.
TX: 3:09:45 PM 00 01 00 10 00 01 00 05 62 03 80 01 00
RX: 3:09:45 PM 00 01 00 01 00 10 00 05 63 03 80 01 00
Access Error : Device reports a unavailable object.
Can you please help me to resolve this error?
Regards,
Shailav
Hi Shailav, Your meter doesn…
Hi Shailav,
Your meter doesn't implement an association view. That is mandatory for DLMS meters. Without that, the client doesn't know what kind of objects the meter can offer.
You need to ask if there is a new firmware update available from the meter vendor.
BR,
Mikko