Hi,
I am completely new to meter reading and DLMS. I have been tasked with reading data from an electric meter.
I have an ip address and a port number.
The meter is Meteronic MT318.
I have been provided a program that already communicates with the meter.
Here are some of the logs of the program:
You can use Gurux template to connect for the meter. Create new meter. Select Gurux as a manufacturer. Change Interface from HDLC to WRAPPER. Set TCP/IP host address and port number. Connect for the meter. You can connect for the meter with Gurux DLMS client. Use the parameters that GXDLMSDirector shows when you select the meter.
It's always easier if you start with GXDLMSDirector and check what meter can do.
Thanks for the reply. I was apple to connect to the meter using GXDLMSDirector after following the steps you wrote and using client address 0x11. However I cannot find Meteronic is not on the list.
Meteronic is not on the list yet. It can be added if you just let me know did you use a low authentication level to establish the connection? If you connect without authentication the client address should be 0x10.
Hi Moataz,
Hi Moataz,
You can use Gurux template to connect for the meter. Create new meter. Select Gurux as a manufacturer. Change Interface from HDLC to WRAPPER. Set TCP/IP host address and port number. Connect for the meter. You can connect for the meter with Gurux DLMS client. Use the parameters that GXDLMSDirector shows when you select the meter.
It's always easier if you start with GXDLMSDirector and check what meter can do.
BR,
Mikko
Hi,
Hi,
Let me know if you can connect and the meter template for Meteronic is added.
BR,
Mikko
Hi Mikko,
Hi Mikko,
Thanks for the reply. I was apple to connect to the meter using GXDLMSDirector after following the steps you wrote and using client address 0x11. However I cannot find Meteronic is not on the list.
Thank you,
Moataz.
Hi Moataz,
Hi Moataz,
Meteronic is not on the list yet. It can be added if you just let me know did you use a low authentication level to establish the connection? If you connect without authentication the client address should be 0x10.
BR,
Mikko
Hi,
Hi,
Support for Meteronic is added. Update manufacturer settings after you start GXDLMSDirector and you can add it directly.
BR,
Mikko
Hi Mikko,
Hi Mikko,
I used Low authentication with password, client address 0X11, interface WRAPPER. I changed nothing else.
Thank you,
Hi,
Hi,
You can use it directly if you select "Hangzhou Meteronic Technology Co., Ltd." as a manufacturer.
BR,
Mikko