New to gurux and electric meters. Need to connect to meter using ip address and port number

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Moataz Gamal , 13 February, 2022
Forums
Gurux.DLMS

Hi,
I am completely new to meter reading and DLMS. I have been tasked with reading data from an electric meter.
I have an ip address and a port number.
The meter is Meteronic MT318.
I have been provided a program that already communicates with the meter.
Here are some of the logs of the program:

[14:15:07.4745]Send: 00 01 00 10 00 01 00 22 60 20 80 02 07 80 A1 09 06 07 60 85 74 05 08 01 01 BE 0F 04 0D 01 00 00 00 06 5F 04 00 FF FF FF 28 00
[14:15:07.8164]Recv: 00 01 00 01 00 10 00 2B 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 10 1C 01 90 00 07

[14:15:07.9752]Send: 00 01 00 10 00 01 00 0D C0 01 81 00 01 00 00 60 01 00 FF 02 00
[14:15:08.4382]Recv: 00 01 00 01 00 10 00 11 C4 01 81 00 09 0B 30 32 31 33 30 30 30 30 30 30 31

[14:15:08.6293]Send: 00 01 00 10 00 01 00 0D C0 01 81 00 01 01 00 00 02 00 FF 02 00
[14:15:09.0510]Recv: 00 01 00 01 00 10 00 0D C4 01 81 00 09 07 56 30 31 2E 30 30 00

[14:15:09.2227]Send: 00 01 00 10 00 01 00 0D C0 01 81 00 01 00 00 2A 00 00 FF 02 00
[14:15:09.6619]Recv: 00 01 00 01 00 10 00 0B C4 01 81 00 09 05 4D 54 33 31 38

[14:15:09.8478]Send: 00 01 00 10 00 01 00 0D C0 01 81 00 08 00 00 01 00 00 FF 02 00
[14:15:10.2853]Recv: 00 01 00 01 00 10 00 12 C4 01 81 00 09 0C 07 E6 02 09 03 0E 0E 24 FF 80 00 02

I need to emulate this functionality. I tried using GXDLMSDirector but Meteronic was not on the manufacturers list.

Any help with how to get started, how to connect, send and receive from the meter through gurux (preferably using .Net) is appreciated.

Thanks & Regards,
Moataz.

Profile picture for user Kurumi

Kurumi

4 years 3 months ago

Hi Moataz,

Hi Moataz,

You can use Gurux template to connect for the meter. Create new meter. Select Gurux as a manufacturer. Change Interface from HDLC to WRAPPER. Set TCP/IP host address and port number. Connect for the meter. You can connect for the meter with Gurux DLMS client. Use the parameters that GXDLMSDirector shows when you select the meter.

It's always easier if you start with GXDLMSDirector and check what meter can do.

BR,
Mikko

Profile picture for user Kurumi

Kurumi

4 years 3 months ago

Hi,

Hi,

Let me know if you can connect and the meter template for Meteronic is added.

BR,
Mikko

Moataz Gamal

4 years 3 months ago

Hi Mikko,

Hi Mikko,

Thanks for the reply. I was apple to connect to the meter using GXDLMSDirector after following the steps you wrote and using client address 0x11. However I cannot find Meteronic is not on the list.

Thank you,
Moataz.

Profile picture for user Kurumi

Kurumi

4 years 3 months ago

Hi Moataz,

Hi Moataz,

Meteronic is not on the list yet. It can be added if you just let me know did you use a low authentication level to establish the connection? If you connect without authentication the client address should be 0x10.

BR,
Mikko

Profile picture for user Kurumi

Kurumi

4 years 3 months ago

Hi,

Hi,

Support for Meteronic is added. Update manufacturer settings after you start GXDLMSDirector and you can add it directly.

BR,
Mikko

Moataz Gamal

4 years 3 months ago

Hi Mikko,

Hi Mikko,

I used Low authentication with password, client address 0X11, interface WRAPPER. I changed nothing else.

Thank you,

Profile picture for user Kurumi

Kurumi

4 years 3 months ago

Hi,

Hi,

You can use it directly if you select "Hangzhou Meteronic Technology Co., Ltd." as a manufacturer.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin