By Rostislav, 28 December, 2021
Forums
Known problems

Hi!

I am using GXDLMSDirector version 8.2.2112.2101.
When associating a fixture, I get the error:

GXDLMSDirector 8.2.2112.2101
Log created 15:52:42
15:52:59 Initializing serial connection.
15:53:01 Send SNRM request.
7E A0 08 02 2F 61 93 78 87 7E
15:53:01
7E A0 08 61 02 2F 73 6D FC 7E
15:53:01 Parsing UA reply succeeded.
15:53:01 Send AARQ request.
7E A0 7D 02 2F 61 10 4C 02 E6 E6 00 60 6E A1 09 06 07 60 85 74 05 08 01 03 A6 0A 04 08 30 30 30 30 30 30 30 8A 02 07 80 8B 07 60 85 74 05 08 02 02 AC 12 80 10 61 54 65 18 21 21 0F 18 13 3A 01 14 11 2C 39 4C BE 34 04 32 21 30 30 00 00 00 00 ED F5 73 31 97 60 6F 71 49 0F 20 4C 9B FF D8 46 A8 DF DE F4 6E 20 E5 67 1E 22 55 F2 E0 70 77 3F 4C A8 FF 03 D6 1F 16 73 13 13 B6 68 59 7E
15:53:01
7E A0 6C 61 02 2F 30 51 00 E6 E7 00 61 5D A1 09 06 07 60 85 74 05 08 01 01 A3 05 A1 03 02 01 00 BE 23 04 21 28 1F 30 00 00 00 00 E4 F4 65 90 28 9A CF 8F E9 AC 80 32 3B 06 37 45 2D F7 9F E1 19 EA 0C 97 83 ED A2 03 02 01 00 88 02 07 80 AA 12 80 10 04 8A 04 8A C0 B8 C0 B8 F8 47 F8 47 F7 1D F7 1D 89 07 60 85 74 05 08 02 02 C1 23 7E
15:53:01 Disconnect request
15:53:02
7E A0 08 61 02 2F 73 6D FC 7E
Gurux.DLMS.GXDLMSException: Connection is permanently rejected. The application context name is not supported.
Meter expects Logical Name referencing.
at GXDLMSDirector.GXDLMSCommunicator.InitializeConnection (Boolean force)
at GXDLMSDirector.GXDLMSDevice.InitializeConnection ()
at GXDLMSDirector.MainForm.Connect (Object sender, GXAsyncWork work, Object [] parameters)

What could be the problem? Thanks in advance for your help!

Profile picture for user Kurumi

Kurumi

3 years 4 months ago

Hi,

Hi,

Check "Logical Name Referencing" from meter settings.

BR,
Mikko

Rostislav

3 years 4 months ago

Hi, Mikko!

Hi, Mikko!
Thanks for your reply!

The problem seems to me deeper. I checked the package in GuruxDLMSTranslator and got the error. I don't understand what the problem is. When Security = None there is no error in GuruxDLMSTranslator.

At first glance, the package contains no errors
7E A0 78 61 02 2F 30 01 99 E6 E7 00 61 69 A1 09 06 07 60 85 74 05 08 01 03 A3 05 A1 03 02 01 0E BE 23 04 21 28 1F 30 00 00 00 00 E4 F4 65 90 28 9A CF 8F B6 EE 80 32 3B 06 34 75 6F 32 48 AA CD 61 1A 1D D3 E3 A4 0A 04 08 30 30 30 30 30 30 30 30 A2 03 02 01 00 88 02 07 80 AA 12 80 10 C9 C3 C9 C3 FE 65 FE 65 90 C3 90 C3 7E B8 7E B8 89 07 60 85 74 05 08 02 02 80 56 7E

Best regards,
Rostislav

Image

Rostislav

3 years 4 months ago

Up

Up

Image

Rostislav

3 years 4 months ago

Up

Up

Image
Profile picture for user Kurumi

Kurumi

3 years 4 months ago

Hi,

Hi,

I can't check this because I don't know the logical name of the meter. Can you add all messages between the client and the meter?

BR,
Mikko

Rostislav

3 years 4 months ago

Mikko,

Mikko,

Logical name = KAC00000001 (obis 0.0.42.0.0.255)

This is the entire data exchange (there is no further exchange):

> 7E A0 08 02 2F 61 93 78 87 7E
< 7E A0 08 61 02 2F 73 6D FC 7E

> 7E A0 7D 02 2F 61 10 4C 02 E6 E6 00 60 6E A1 09 06 07 60 85 74 05 08 01 03 A6 0A 04 08 30 30 30 30 30 30 30 8A 02 07 80 8B 07 60 85 74 05 08 02 02 AC 12 80 10 61 54 65 18 21 21 0F 18 13 3A 01 14 11 2C 39 4C BE 34 04 32 21 30 30 00 00 00 00 ED F5 73 31 97 60 6F 71 49 0F 20 4C 9B FF D8 46 A8 DF DE F4 6E 20 E5 67 1E 22 55 F2 E0 70 77 3F 4C A8 FF 03 D6 1F 16 73 13 13 B6 68 59 7E
< 7E A0 6C 61 02 2F 30 51 00 E6 E7 00 61 5D A1 09 06 07 60 85 74 05 08 01 01 A3 05 A1 03 02 01 00 BE 23 04 21 28 1F 30 00 00 00 00 E4 F4 65 90 28 9A CF 8F E9 AC 80 32 3B 06 37 45 2D F7 9F E1 19 EA 0C 97 83 ED A2 03 02 01 00 88 02 07 80 AA 12 80 10 04 8A 04 8A C0 B8 C0 B8 F8 47 F8 47 F7 1D F7 1D 89 07 60 85 74 05 08 02 02 C1 23 7E

> 7E A0 08 61 02 2F 73 6D FC 7E
Gurux.DLMS.GXDLMSException: Connection is permanently rejected. The application context name is not supported.

Best regarqs,
Rostislav

Profile picture for user Kurumi

Kurumi

3 years 4 months ago

Hi Rostislav,

Hi Rostislav,

The server system title is 8 bytes long value. Have you modified the source code because there are only 7 bytes? Your meter is also returning an invalid reply. ApplicationContextName is invalid. ResultSourceDiagnostic should be ciphered and the server system title is missing.

BR,
Mikko

Profile picture for user HEMANT KUMAR

HEMANT KUMAR

3 years 2 months ago

MY METER NOT CONNECTED SINCE

MY METER NOT CONNECTED SINCE THEY POP UP INVALID

Profile picture for user Kurumi

Kurumi

3 years 2 months ago

In reply to MY METER NOT CONNECTED SINCE by HEMANT KUMAR

Hi Hemant Kumar,

Hi Hemant Kumar,

Please, create a new topic if you have a new question.

BR,
Mikko

Rostislav

2 years 10 months ago

Hi, dr. Mikko!

Hi, dr. Mikko!

I figured out the problem.
The fact is that, apparently, the GXDLMSDirector program parses the package by sequentially processing the tags. The vulnerability of such a mechanism is that when the BE and A4 tags are swapped, such an algorithm crashes during operation. The way out of this situation would be to parse the BE tag with an intermediate search for the A4 tag (if it has not been encountered before) inside the package as needed.

The forum thread can be considered closed.

  • Log in or register to post comments
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Fri, 05/09/2025 - 13:03
    Gurux.DLMS.Python 1.0.181
  • Wed, 05/07/2025 - 16:09
    Gurux.DLMS.Android 2.0.14
  • Tue, 05/06/2025 - 09:34
    gurux.dlms.c 9.0.2505.0601
  • Tue, 05/06/2025 - 08:51
    GXDLMSDirector 9.0.2505.0601
  • Tue, 05/06/2025 - 08:26
    gurux.dlms.java 4.0.79

New forum topics

  • I LOST MY CRYPTO, HOW DO I RECOVER IT? iFORCE HACKER RECOVERY
  • GXNet python implementation hangs on close
  • Conexión Landis ZMG310 Protocolo IEC
  • I need function of below OBIS code
  • How communicating with meter using proparatory command
More

Who's new

  • John Willis
  • nnn
  • raghavrg09
  • Haithem_boubaker
  • sobatih
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin