Hello,

I am trying to connect Itron SL7000 meter via DLMS Director. I am using Utility RS232 port and Moxa UPort 1150 device for this. You can find wiring diagram at attachment.

I tried default parameters (None auth. and Low auth.) but it not worked. I also tried some parameters that I found in forum. You can find my parameters at below.

Manufacturer: Actaris Electricity
Interface: HDLC
Logical Name Referencing: true
Auth: Low
Password: ABCDEFGH
Client Address: 1
Wait Time: 00:00:05
Address Type: Default
Logical Server: 1
Physical Server: 11
Verbose: false
Media: Serial
- Baudrate: 300
- Parity: Even
- Stop Bits: One
- Data bits: 7

Could anyone help me about this issue? I don't know what should I do.

Thanks.

Image
Profile picture for user Kurumi

Kurumi

5 years 5 months ago

Hi,

Hi,

Change start protocol from HDLCWithModeE to HDLC. You need to try with different baud rates. Start with 9600 and 4800. I believe that the reason why communication fails is the wrong serial port settings.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101
  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202

New forum topics

  • GXObisValueItem entries without MaskSize appear to be interpreted as bit flags
  • CheckedListBox incorrectly selects GXObisValueItem Value=0 for non-zero values
  • UIValueType=TextBox is rendered as CheckedListBox when Values are defined
  • Displaying mapped UInt8 values as read-only text in GXDLMSDirector
  • Python example can't read date from meter using WRAPPER connection
More

Who's new

  • barez fredj
  • MiguelC
  • Hichem Nasraoui
  • Matt_Plumer
  • King Won
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin