That other meter might be the reason. Try to connect using the serial number of the meter.
Change "Address Type" from Default to SerianNumber and set the serial number.
You should see traces as a default.
You can check this. Find "TraceLevel" from appsettings.json.
It should be "Verbose". You can see send and received data in the command prompt.
Hi,
Hi,
Your meter is sending UA reply twite.
http://www.gurux.fi/GuruxDLMSTranslator?translate=7EA01E210373C37A81801…
This looks strange. Can you read the meter with GXDLMSDirector? Have you modified the source code?
BR,
Mikko
Hi Mikko
Hi Mikko
I cannot read the meter. I get the error when i try to connect the meter.
The source is not modified.
There is a sub-meter via RS485, could that be a reason?
/Henrik
Hi,
Hi,
That other meter might be the reason. Try to connect using the serial number of the meter.
Change "Address Type" from Default to SerianNumber and set the serial number.
BR,
Mikko
Hi Again.
Hi Again.
That worked perfectly, thanks.
The trace is nice. can I view it somewhere for the Gurux.AMI?
Hi,
Hi,
You should see traces as a default.
You can check this. Find "TraceLevel" from appsettings.json.
It should be "Verbose". You can see send and received data in the command prompt.
BR,
Mikko
Thanks for your help.
Thanks for your help.