By Mohanraj , 28 December, 2020
Forums
General discussion

Hi Mikko,

We are trying to download profilegeneric data from meter using ANSI C library. At point DLMS stack is getting struck at getCount function . Attached Tx and Rx log also the function call history.
For your information , meter is working with GuruxDLMSExplorer

Tx : 7E A0 07 03 41 93 5A 64 7E
Rx : 7E A0 20 41 03 73 3E 9D 81 80 14 05 02 02 26 06 02 00 9B 07 04 00 00 00 01 08 04 00 00 00 01 B6 DC 7E

Tx : 7E A0 44 03 41 10 B3 E1 E6 E6 00 60 36 A1 09 06 07 60 85 74 05 08 01 01 8A 02 07 80 8B 07 60 85 74 05 08 02 01 AC 0A 80 08 31 31 31 31 31 31 31 31 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 00 1E 1D FF FF D4 34 7E
Rx : 7E A0 37 41 03 30 21 79 E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 10 14 00 89 00 07 38 2C 7E

Tx : 7E A0 19 03 41 32 3A BD E6 E6 00 C0 01 81 00 07 00 00 5E 5B 0A FF 03 00 5D CB 7E
Rx : 7E A0 B4 41 03 52 96 31 E6 E7 00 C4 01 81 00 01 09 02 04 12 00 01 09 06 00 00 60 01 00 FF 0F 02 12 00 00 02 04 12 00 01 09 06 00 00 60 01 01 FF 0F 02 12 00 00 02 04 12 00 01 09 06 01 00 00 02 00 FF 0F 02 12 00 00 02 04 12 00 01 09 06 00 00 5E 5B 09 FF 0F 02 12 00 00 02 04 12 00 01 09 06 00 00 5E 5B 0B FF 0F 02 12 00 00 02 04 12 00 01 09 06 00 00 5E 5B 0C FF 0F 02 12 00 00 02 04 12 00 01 09 06 01 00 00 04 02 FF 0F 02 12 00 00 02 04 12 00 01 09 06 01 00 00 04 03 FF 0F 02 12 00 00 02 04 12 00 01 09 06 00 00 60 01 04 FF 0F 02 12 00 00 AB 60 7E

Tx : 7E A0 19 03 41 54 0A BB E6 E6 00 C0 01 81 00 07 00 00 5E 5B 0A FF 02 00 85 D2 7E
Rx : 7E A0 4D 41 03 74 EA FB E6 E7 00 C4 02 81 01 00 00 00 01 00 37 01 01 02 09 0A 07 50 44 4C 50 52 30 31 0A 0A 4C 61 6E 64 69 73 2B 47 79 72 0A 03 34 30 30 0A 01 34 0A 02 43 32 0A 08 31 30 2D 36 30 20 41 20 12 00 01 11 01 12 00 00 9C BA 7E

Tx : 7E A0 19 03 41 76 1A B9 E6 E6 00 C0 01 81 00 07 01 00 5E 5B 00 FF 03 00 4C 96 7E
Rx : 7E A2 21 41 03 96 AE 27 E6 E7 00 C4 02 81 00 00 00 00 01 00 82 02 09 01 26 02 04 12 00 08 09 06 00 00 01 00 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 1F 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 33 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 47 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 20 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 34 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 48 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 21 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 35 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 49 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 0D 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 0E 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 09 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 01 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 03 07 00 FF 0F 02 12 00 00 02 04 12 00 01 09 06 00 00 60 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 00 00 5E 5B 08 FF 0F 02 12 00 00 02 04 12 00 01 09 06 00 00 5E 5B 00 FF 0F 02 12 00 00 02 04 12 00 01 09 06 00 00 00 01 00 FF 0F 02 12 00 00 02 04 12 00 01 09 06 00 00 60 02 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 00 00 00 01 02 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 01 08 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 05 08 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 08 08 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 09 08 00 FF 0F 02 12 00 00 02 04 12 00 04 09 06 01 00 01 06 00 FF 0F 02 12 00 00 02 04 12 00 04 09 06 01 00 01 06 00 FF 0F 05 12 00 00 02 04 12 00 04 09 06 01 00 09 06 00 FF 0F 02 12 00 00 02 04 12 00 04 09 06 01 00 09 06 00 FF 0F 05 87 AB 7E

Tx : 7E A0 13 03 41 98 C4 6B E6 E6 00 C0 02 81 00 00 00 01 73 7F 7E
Rx : 7E A0 BC 41 03 B8 1A 9C E6 E7 00 C4 02 81 01 00 00 00 02 00 81 A5 12 00 00 02 04 12 00 03 09 06 01 00 17 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 2B 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 3F 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 01 18 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 01 38 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 01 4C 07 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 00 00 60 01 C9 FF 0F 02 12 00 00 02 04 12 00 04 09 06 01 00 01 04 00 FF 0F 02 12 00 00 02 04 12 00 04 09 06 01 00 01 04 00 FF 0F 05 12 00 00 E5 EB 7E

Thanks
Mohanraj

Image

Mohanraj

5 years 7 months ago

Hi Mikko,

Hi Mikko,

Any update please or any changes required from meter end?

Thanks
Mohan Raj

Profile picture for user Kurumi

Kurumi

5 years 7 months ago

Hi,

Hi,

Meter returns the wrong frame length. Max PDU size is 137 bytes and meter returns more than 500 bytes. You need to fix this.

BR,
Mikko

Mohanraj

5 years 7 months ago

In reply to Hi, by Kurumi

Hi Mikko,

Hi Mikko,

please suggest us where this has to be fixed?

Is it in meter firmware?
I do not think. Because GXDLMSDirector is working properly.

If it is in our application please tell us where and how?

Thanks
Mohanraj

Profile picture for user Kurumi

Kurumi

5 years 7 months ago

Hi Mohanraj,

Hi Mohanraj,

Yes, this is in meter firmware. The reason why GXDLMSDirector works is that it doesn't care how much memory is allocated. ANSI C version allocates only the needed amount of memory.

You can fix this to the client side if you change this line:
//Allocate 50 bytes more because some meters count this wrong and send few bytes too many.
con_initializeBuffers(connection, 50 + connection->settings.maxPduSize);

Change 50 to 500 and you can read your meter.

BR,
Mikko

Mohanraj

5 years 7 months ago

In reply to Hi Mohanraj, by Kurumi

Hi Mikko,

Hi Mikko,

Thank you for the suggestion. working after changing the buffer size at client side.

Thanks
Mohanraj

Profile picture for user Kurumi

Kurumi

5 years 7 months ago

Hi,

Hi,

I have to point out that this is only a fast fix. This should be fixed for the meter or it might cause problems later.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Possible memory leak in file dlms.c, getCompactArrayItem(), getCompactArrayItem2()
  • Official Gurux.DLMS.Client.Example.Net fails during High GMAC secure association (Invalid PDU), while Gurux Director connects successfully
  • gurux_dlms.GXDateTime.GXDateTime object Error in Python
  • T_APPL_DATA_LN_N1 subtest 3 fails on an LN-only server regardless of the response to a non-existing-object GET
  • Version mismatch between Gurux.DLMS 9.x and Gurux.Common/Gurux.Serial 8.x
More

Who's new

  • bgPxfNlRsIzamJ…
  • sheldon_ariola
  • DtkfMfCBWyhwcO…
  • CRISTIAN MAXENTI
  • mPDxPIQgXwPXoV…
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin