Hi Mikko,

Hope you are safe and doing good. Clarification is required regarding ANSI C library for microcontroller client side.

gxProfileGeneric prfileGen;
if we call com_readRowsByEntry(&prfileGen,....) or com_readRowsByRange(&prfileGen,....) multiple times with different parameters like(large from and to date or more rows) then for the consecutive calls memory will be deallocated and allocated newly or how is it?
How do we free prfileGen object so that memory can be used for someother purpose

Note : we are not enabled GX_DLMS_MICROCONTROLLER macro

Thanks
Mohan

Profile picture for user Kurumi

Kurumi

5 years 7 months ago

Hi Mohan,

Hi Mohan,

You can release buffer with obj_clearProfileGenericBuffer;
Something like:

gxProfileGeneric pg;
INIT(...)
READ...
obj_clearProfileGenericBuffer(&pg.buffer);

BR,
Mikko

Mohanraj

5 years 7 months ago

In reply to Hi Mohan, by Kurumi

Hi Mikko, Thank you

Hi Mikko,

Thank you

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More

Who's new

  • CTKNhZElptjSlOrpkXl
  • YCbccqfLGRMnlCWoJhXP
  • Malcolmactig
  • mhliang
  • Kevinmug
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin