How is it possible that I can set the clock one hour back in time and NOT one hour forward?
Is it a setting in Gurux DLMS Director?

It concerns a EMH LZQJ-XC.

dntimmie

6 years ago

I made a little progression.

I made a little progression. I found out when I check 'Ignore Time Zone' and 'Ignore Time Status', I can set the meter one hour back and when I uncheck these parameters I can set the meter one hour forward.
Strange. I excpected that I always can set the meter's time independent of these parameters.

Profile picture for user Kurumi

Kurumi

6 years ago

Hi,

Hi,

I'm sorry that I haven't replied to your email. For some reason, I didn't notest it.

You can find more information from the clock here:
http://www.gurux.fi/Gurux.DLMS.Objects.GXDLMSClock

BR,
Mikko

dntimmie

6 years ago

I read the node, but it gives

I read the node, but it gives not the answer to my question: I found out when I check 'Ignore Time Zone' and 'Ignore Time Status', I can set the meter one hour back and when I uncheck these parameters I can set the meter one hour forward.
Strange. I excpected that I always can set the meter's time independent of these parameters.

Profile picture for user Kurumi

Kurumi

6 years ago

Hi,

Hi,

If you ignore time-zone and time status, deviation and DST flags are ignored. In this case, the meter expects that the received date-time is using the same time zone as the meter.

If the time zone is sent meter counts time using offset between the sent deviation and the meter time zone.

Note! Some meters can't handle deviation when a new time is set. I can't remember how EMH LZQJ-XC handles this.

BR,
Mikko

dntimmie

6 years ago

In reply to Hi, by Kurumi

When I use Combimaster (the

When I use Combimaster (the tool that comes with EMH) I can set time back and forward.

Profile picture for user Kurumi

Kurumi

6 years ago

Hi,

Hi,

Can you get any trace from Combimaster bytes and add write bytes here so I can check how it handles deviation?

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Landis E650 meter reading over DLMS
  • class_id = 40, version = 2, pushsetup Unparsed data frame
  • GXObisValueItem entries without MaskSize appear to be interpreted as bit flags
  • CheckedListBox incorrectly selects GXObisValueItem Value=0 for non-zero values
  • UIValueType=TextBox is rendered as CheckedListBox when Values are defined
More

Who's new

  • Sayang
  • q80435762@gmail.com
  • ONCAK
  • Berhasil
  • ratirvivege1979
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin