By tagmout , 11 July, 2020
Forums
General discussion

can we read with gxdlmsdirector the meters that share a gateway and are identified by their AMR ?

we have just ip address of the gateway .

Profile picture for user Kurumi

Kurumi

5 years 11 months ago

Hi,

Hi,

That depends from the GW. You need to ask is meter address used to identify the meter from the meter manufacturer or how they have done it. It might be that they are also using DLMS gateway service, but only the gateway manufacturer will know this. Gurux libraries are supporting both ways.

BR,
Mikko

tagmout

5 years 11 months ago

Hey ,

Hey ,

Yes , as i said the meter is identified with an AMR identifier and the GW with an IP @ , so how we can access the meter with GXDLMSDirector ?

Thanks ,

Profile picture for user Kurumi

Kurumi

5 years 11 months ago

Hi,

Hi,

Is there only one meter behind every GW? If there is only one meter and you are using static IP address you can read the meter directly using TCP/IP address.

BR,
Mikko

tagmout

5 years 11 months ago

Hey ,

Hey ,

There is a lot of meters which differs with code AMR .

Thanks.

Profile picture for user Kurumi

Kurumi

5 years 10 months ago

Hi,

Hi,

If there are a lot of meters, then you need to ask from the GW manufacturer how the meter address is used. DLMS allows several ways to define how to talk with the meter.

BR,
Mikko

tagmout

5 years 10 months ago

Hey ,

Hey ,

They use an AMR code to access the meters , so how we can use that in GXDLMSDirector ?
Thanks

Profile picture for user Kurumi

Kurumi

5 years 10 months ago

Hi,

Hi,

It depends from from the meter manufacturer how AMR code is generated. You need to ask this from the GW vendor.

BR,
Mikko

tagmout

5 years 10 months ago

Hey ,

Hey ,

In the case of one meter behind the GW , how we can read the meter with GXDLMSDirector.

Thanks

Profile picture for user Kurumi

Kurumi

5 years 10 months ago

Hi,

Hi,

There are several ways how to do it and I can't say anything because I don't know what GW you are using. Also, some GW manufacturers are using custom solutions. Ex. you need first select the meter that you want to communicate with. You need to ask this from the GW manufacturer.

BR,
Mikko

tagmout

5 years 10 months ago

Hey Kurumi ,

Hey Kurumi ,

Our architecture is summarized in the attached picture . in that cas , which interface of device properties we have to use HDCL OR WRAPPER .
If You can please give us the full device properties that we have to use .

Thank You .

Image
Profile picture for user Kurumi

Kurumi

5 years 10 months ago

Hi,

Hi,

Is your Gateway like Moxa or is it from the meter manufacturer?
If it's Moxa, then you need to use HDLC framing. Are all the meters using the same communication channel or is there an own line for each of the meters?

BR,
Mikko

tagmout

5 years 10 months ago

Yes , each meter have an own

Yes , each meter have an own line identified by a serie code , still there is a connection issue . Can You please give us the parameters connection that we have to use with GXDLMSDirector .
Thank You ,

Profile picture for user Kurumi

Kurumi

5 years 10 months ago

Hi,

Hi,

Try to change "Address Type" to "Serial Number" in GXDLMSDirector settings. Then set the serial number of the meter. This is one way how GW manufacturers have done it. I hope it helps.

BR,
Mikko

tagmout

5 years 10 months ago

Hi Mikko ,

Hi Mikko ,
below our situation :
GXDLMSDirector is running inside the Headquarters location and PPC Gateway has a modem that can connect to the Headquarters network and join its VPN with a static IP address ; Meter 1 and Meter 2 are DLMS HDLC meters connected to the Gateway on serial RS485. We Can ping the gateway’s VPN IP from a computer inside the Headquarters VPN but we can’t telnet the gateway, there is a login and password . that may be the problem ?

BR,

Profile picture for user Kurumi

Kurumi

5 years 10 months ago

Hi,

Hi,

Because I don't know what gateway you are using the reason might be anything.
You should ask this from the gateway manufacturer because I can't help you with this.

BR,
Mikko

tagmout

5 years 10 months ago

Hi Mikko ,

Hi Mikko ,

Thank You a lot for your reactions , for the gateway is PPC and the meters are Elster . Can You please tell me the question that i should to ask the gateway manufacturer ?

Profile picture for user Kurumi

Kurumi

5 years 10 months ago

Hi,

Hi,

You need to ask how to communicate with the GW. Is GW transparent or do you need to talk with it and in what format?

BR,
Mikko

tagmout

5 years 10 months ago

Hi Mikko ,

Hi Mikko ,

The gateway send the received data in broadcast and the meter with the convenable serial number replies.

Can You please tell me how to configure that in GXDLMSDirector for connecting to the meter .

Thank You

Profile picture for user Kurumi

Kurumi

5 years 10 months ago

Hi,

Hi,

If the serial number is used as server address then change "Address type" from Default to "SerialNumber" and set meter serial number to the "Serial number" field.

BR,
Mikko

tagmout

5 years 10 months ago

In reply to Hi, by Kurumi

hi Mikko ,

hi Mikko ,

there just 'default' on the choices .

Can You see the attached picture .

BR,

tagmout

5 years 10 months ago

hi Mikko ,

hi Mikko ,

there just 'default' on the choices .

Can You see the attached picture .

Image

tagmout

5 years 10 months ago

Hi ,

Hi ,

We are using Elster Meter . there is just default in Address Type.

tagmout

5 years 10 months ago

Hi ,

Hi ,

In our situation , we have to use Gateway ?

BR,

Image
Profile picture for user Kurumi

Kurumi

5 years 10 months ago

Hi,

Hi,

I don't know if your version from the Elster meter supporting the serial number. You need to ask it from the meter vendor. I believe that your GW manufacturer is not supporting DLMS gateway commands, but you need to ask it from the GW vendor.

BR,
Mikko

tagmout

5 years 9 months ago

Hi mikko ,

Hi mikko ,
I hope you feel great ,

Our Gateway implements DLMS / COSEM using BPL-TCP / IP transport for smart meters with RS-485.

Elster smart meters only support DLMS / COSEM using data transports outside the scope of the project:
• AS1440 ==> "AM500 PLC S-FSK module"
• AS220 ==> "AM100 module - GSM / GPRS".

For this reason, our Gateway implements DLMS / COSEM on the BPL-TCP / IP data transport

EN 62056-21Defines the protocol on the RS-485 interface between the Smart Meter and the device reading the meter

We can read in that case the elster AS220 and A1440 meters with GXDLMSDirector ?

BR,

Image
Profile picture for user Kurumi

Kurumi

5 years 9 months ago

Hi,

Hi,

I check this from this AM100 flyer:
https://www.elstersolutions.com/assets/products/products_elster_files/A…
AM100 might support EN62056-21 or DLMS/COSEM.

EN 62056-21 is not DLMS. It's totally different standard. Because we don't have AM100 I can't check it. If your AM100 is supporting DLMS you can read it.

BR,
Mikko

tagmout

5 years 9 months ago

Our Meters are connected to

Our Meters are connected to the gateway by the RS485 cable ,
In that case , If the gateway supports DLMS and the RS-485 don't support ; we can read it ? Can you please check the RS-485 meters answers in the attached picture .

Image
Profile picture for user Kurumi

Kurumi

5 years 9 months ago

Hi,

Hi,

You need to ask this from the meter manufacturer. Only they know it for sure.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin