By kobe , 22 August, 2017
Forums
Gurux.SMS

Hello,

Today I tried to find some code to control a sms modem of schneider electric, with at commands and c#. i tried to use this library but everytime I open the connection, the error "Pin is needed" is shown.

I had a look in the source code and it seems to be a problem in the code sheet GXSMS.cs, in the open method the program sends the AT command "AT+CPIN?\r" at line 1196. Then the modem replys with "+CPIN: READY", the code also waits to get this command but there is a problem there. The SendCommand method seems unable to give this as a reply, because there is no OK in this reply.

Is my modem not following an agreement, that states an OK is needed?
Is this maybe a bug in the code?
This seems critical to me, do other modems give a different reply?

Can someone have a look at this?
At the moment I have changed the code so the READY command is accepted without OK.

Kind regards.

Profile picture for user Kurumi

Kurumi

8 years 11 months ago

Error when opening a connection

Hi,

We tested this with few modems. All are returning OK at the end:
AT+CPIN?
+CPIN: READY
OK

Are you receiving \r\n after READY?
BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200
  • Mon, 06/15/2026 - 08:52
    gurux.dlms.c 9.0.2606.1501

New forum topics

  • Service not known error on gprs communication
  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
More

Who's new

  • OLaneHycle
  • LxfgLnoisbruoL…
  • SunbetLith
  • highclassrightway
  • sapran
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin