Status mapping
This object explains the bits in a meter status word by linking them to entries in a status reference table. It separates the current status value from the meaning of each bit.
When to use it
Use it to interpret an alarm or event status word whose bits refer to a shared status table.
Attributes
1. Logical name
The OBIS code that identifies this object instance in the meter. Use it to distinguish this instance from other objects of the same class.
2. Status word
Holds the current status value. Its contents are interpreted as bits even when the value is carried in a number or string.
3. Mapping table
Identifies the reference status table and maps bit positions to its entries. A starting entry can describe consecutive mappings, or a list can map each bit separately.
Actions
There are no actions available for this object type.