By Gurux Documentation , 10 November, 2026

Short name association

This object describes a client connection that accesses meter attributes through short addresses. It provides the address information needed to find objects in that connection.

When to use it

Use it when connecting to a meter that uses short name referencing and building its object list.

Attributes

1. Logical name

The OBIS code that identifies this object instance in the meter. Use it to distinguish this instance from other objects of the same class.

2. Object list

Lists the objects visible to the client, with each object's base short name, class, version and logical name.

3. Access rights list

Describes which attributes can be read or written and which methods can be called.

4. Security setup reference

Identifies the Security setup object responsible for this association's communication protection.

Versions

Attribute availability in the supplied component help depends on the object version (version 0: attributes 1-2; version 1: attributes 1-2; version 2: attributes 1-4). Use the version-specific descriptions above where provided.

  • Log in or register to post comments
  • Create new account
  • Reset your password

Book navigation

  • Activity calendar
  • Association Logical Name
  • Auto Connect
  • Auto answer
  • Clock
  • Compact data
  • Data
  • Demand register
  • Disconnect control
  • Extended register
  • GPRS modem setup
  • GSM diagnostic
  • IEC HDLC setup
  • IEC local port setup
  • IPv6 setup
  • Limiter
  • M-Bus Client
  • M-Bus master port setup
  • M-Bus slave port setup
  • MAC address setup
  • Modem configuration
  • PPP setup
  • Profile generic
  • Push Setup
  • Register
  • Register Monitor
  • Register table
  • SAP assignment
  • Script table
  • Security setup
  • Single action schedule
  • Special days table
  • Status mapping
  • Tcp Udp Setup
  • Utility tables
  • Överföring av programvaruavbildning
  • Manufacturer custom objects
  • Account
  • Arbitrator
  • Array manager
  • Charge
  • CoAP diagnostics
  • CoAP setup
  • Communication port protection
  • Credit
  • Data protection
  • Function control
  • G3-PLC 6LoWPAN setup
  • G3-PLC MAC layer counters
  • G3-PLC MAC setup
  • LLC SSCS setup
  • LTE monitoring
  • M-Bus diagnostics
  • M-Bus port setup
  • Network time setup
  • Parameter monitor
  • PRIME application identification
  • PRIME MAC counters
  • PRIME MAC functional parameters
  • PRIME MAC setup
  • PRIME network administration data
  • PRIME physical layer counters
  • S-FSK active initiator
  • S-FSK MAC counters
  • S-FSK physical and MAC setup
  • S-FSK reporting system list
  • S-FSK synchronisation timeouts
  • Schedule
  • Short name association
  • STS payment token settings
  • Tariff plan
  • Token gateway
  • Twisted pair setup
  • Wireless mode Q channel
  • IPv4 setup
  • Register activation

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Money Changer Indorate Prima Javalas Itc Kuningan Telp/Wa 081930338564
  • Money Changer Valuta Artha Mas Telp/Wa 081930338564
  • Layanan KCU THAMRIN No Cs.0817 819 444
  • Arthamas Citra Mandiri Money Changer Telp/Wa 081930338564
  • KCU THAMRIN No Cs.0817 819 444
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin