Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Node
By Administrator , 4 August, 2025

GXDLMSDirector 9.0.2508.0401

The following important issues are resolved in this version:
The user interface for data protection implemented.

By Administrator , 4 August, 2025

The user interface for data protection implemented.

Project
GXDLMSDirector
Status
Closed (fixed)
Priority
Normal
Category
Feature request
By Administrator , 4 August, 2025

Gurux.DLMS.Net 9.0.2508.0401

The following important issues are resolved in this version:
Data protection GetNames fixed.

By Administrator , 4 August, 2025

Data protection GetNames fixed.

Project
Gurux.DLMS.Net
Status
Active
Priority
Normal
Category
Bug report
By Usuhuu , 4 August, 2025

Taking data from 2 Holley DTSD545 smart meters in one port

Forums
DLMSDirector

Hi,
I want to retrieve data from two Holley DTSD545 smart meters using a single RS-485 communication port. I can read data from the first meter, but when I try to add the second meter, it can't connect.

By Sravanti , 4 August, 2025

US Association Implementation with GuruxServer using ESP32

Forums
Gurux.DLMS

Hi Kurumi,

I have worked on basic PC association by adding different objects, read and write attributes value with GuruxServer in ESP32.
Now we are trying to work on US Association with encryption and authentication. Could you please share any basic example for US Association from ESP32 GuruxServer

Thank you

By dbrandy , 3 August, 2025

Hexing HXE115-KP

Forums
DLMSDirector

Good afternoon Kurumi,

I'm trying to connect to Hexing HXE115-KP with Gurux GXDLMSDirector Version 9.0.2506.2601.

The IEC62056-21 protocol handshake is executed successfully.

By Jimmy , 2 August, 2025

Image Transfer-Data Block Unavailable

Forums
Gurux.DLMS

Hi, Mikko,

By Pablob , 31 July, 2025

ReadWriteDenied on STRING Object

Forums
Gurux DLMS for ANSI C

Hello,

I have a DLMS server running on a 32-bit MCU and a DLMS host also running on a 32-bit MCU, communicating via PLC. Both work correctly: I have created several objects on the server and can successfully connect, get the association view, perform read/write operations, and close the connection properly.

By vadiraj Revankar , 30 July, 2025

Troubleshooting UA Parsing Failures in DLMS/COSEM over Custom USB Serial on Android (No GXMedia)

Forums
Gurux DLMS for Android

I'm building a DLMS/COSEM client on Android using custom USB serial communication (no GXSerial/GXMedia). I send an SNRM request and receive a UA response that starts and ends with 0x7E, but the Gurux Java parser treats it as malformed.

Works:
Genus and Landis+Gyr meters: UA parsed correctly.

Fails:
HPL and L&T meters: UA response appears malformed.

The same configuration (client address, baud rate, etc.) works fine in the Gurux DLMS demo app.

Pagination

  • First page
  • Previous page
  • …
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • Page 42
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • …
  • Next page
  • Last page
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101
  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202

New forum topics

  • Need RJ45 pin configuration for Saral 300 and Saral 305 Secure meters
  • Query Regarding Class 63 Status Mapping Support in Gurux DLMS Python
  • Inhemeter
  • DLMS Server - Profile Generic - can't add too many items to profile generic capture object - how to set maximum profile entries
  • HDLC Frames sequencing