By Administrator , 12 September, 2025

HashAlgorithm: SHA256withECDSA renamed to SHA_256_WITH_ECDSA and SHA384withECDSA to SHA_384_WITH_ECDSA.

Project
Gurux.DLMS.Android
Status
Closed (fixed)
Priority
Normal
Category
Feature request
By Administrator , 12 September, 2025

gurux.dlms.java 4.0.82

The following important issues are resolved in this version:

HashAlgorithm: SHA256withECDSA renamed to SHA_256_WITH_ECDSA and SHA384withECDSA to SHA_384_WITH_ECDSA.
GXDLMSTranslator: add calling-Ae-qualifier tag.

By Administrator , 12 September, 2025

GXDLMSTranslator: add calling-Ae-qualifier tag.

Project
gurux.dlms.java
Status
Closed (fixed)
Priority
Normal
Category
Support request
By Administrator , 12 September, 2025

HashAlgorithm: SHA256withECDSA renamed to SHA_256_WITH_ECDSA and SHA384withECDSA to SHA_384_WITH_ECDSA.

Project
gurux.dlms.java
Status
Closed (fixed)
Priority
Normal
Category
Feature request
By atuldd , 12 September, 2025

Regarding the dlms android project

Forums
Gurux DLMS for Android

In HPL meters, sometimes we receive values with the scalar already applied, while other times the response comes without the scalar, requiring us to divide the value by 1000. Why does this inconsistency occur, even in meters of the same make?

By Rajan , 11 September, 2025

DLMS conformance test using this C library

Forums
Gurux DLMS for ANSI C

Hi,

Is this C library DLMS certified?
I understand that the user implementation based on this library can have issues due to verity of reasons, but this query is specifically for the library part.

By ksk , 9 September, 2025

Python example

Forums
Gurux.DLMS

This is my first time trying to get data on DLMS in python.

GXDLMSDirector connects everything, everything is visible.
I tried the example from Gurux.DLMS.Client.Example.python/main.py and it also reads everything, but it reads all the parameters.

Is there an example of code where I could read the list of OBIS codes that I need, because everything I tried didn't work for me?

By hasimalpkaya , 9 September, 2025

Apator OTUS1 reading via WRAPPER

Forums
DLMSDirector

Hi,

Iam trying to read Apator OTUS meter via Wrapper.
I have security packages and manufacturer tool, but I can not read the meter so far.
I can read some objects trough public association, but I need to read management association.
I can read the configuration of meter via maanufacturer tool and I can see the management access is HLSGMAC and client address etc. But I can not manege the gurux settings.
Could you please help.
I can share the communication log of manufacturer tool by e mail.

Many thanks

By NovakJ , 9 September, 2025

Landis gyr E660

Forums
DLMSDirector

I have a Landis+Gyr E660 with an Ethernet module E66C.
I can connect to it using the Interface Wrapper (client address 10, logical server 1, physical server 1, authentication set to none).

However, with this setup I only receive serial numbers and similar information.
I need to read the actual metering data.

Any advice on how to properly connect to it would be greatly appreciated.

By Sravanti , 9 September, 2025

Gurux DLMS DataCollector Issue

Forums
Gurux.DLMS

Hi Kurumi,

Pagination

  • First page
  • Previous page
  • …
  • Page 28
  • Page 29
  • Page 30
  • Page 31
  • Page 32
  • Page 33
  • Page 34
  • Page 35
  • Page 36
  • …
  • Next page
  • Last page
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin