If the devices are different, check that they have the same meter firmware.
You didn't tell what you tried to read, but I believe it's a profile generic.
You can usually ignore the Invalid frame error if you read only a few days from the profile generic at a time. So decrease the number of days that you try to read in one sitting.
Hi, If the devices are…
Hi,
If the devices are different, check that they have the same meter firmware.
You didn't tell what you tried to read, but I believe it's a profile generic.
You can usually ignore the Invalid frame error if you read only a few days from the profile generic at a time. So decrease the number of days that you try to read in one sitting.
BR,
Mikko
Hi. Found my own mistake…
Hi.
Found my own mistake. Thanks.