  3. Error when trying to read meter with GXDLMSDirector.

Error when trying to read meter with GXDLMSDirector.

By vaibhav, 30 May, 2023
Forums
DLMSDirector

Hello,

I got some errors when I was trying to read the DLMS meter with "GXDLMSDirector".

Please suggest solutions.

Image
Profile picture for user Kurumi

Kurumi

3 months 4 weeks ago

Hi, Please, don't add…

Hi,

Please, don't add pictures. They are hard to read.
One of your settings is wrong and the meter doesn't reply.

What meter do you try to read (model and manufacturer) and what communication channel you are using (TCP/IP, serial)?

BR,
Mikko

vaibhav

3 months 3 weeks ago

model: L&T Electrical &…

Following Information on the meter

model: L&T Electrical & Automation (Three Phase HTCT Multi-Port Meter)
manufacturer: ER300P
communication Channel: optical Prop to Serial Port USB.

Please suggest.

Profile picture for user Kurumi

Kurumi

3 months 3 weeks ago

Hi, First, make sure that…

Hi,

First, make sure that the cable of the optical probe is downward.

If I remember right the ER300P is not using Mode E, so select HDLC to interface type.
Check from the meter documentation what is the used baud rate and you should be able to connect.

BR,
Mikko

vaibhav

3 months 3 weeks ago

Following is the …

Following is the configuration info:

Name: Larsen Toubro
Manufacturer: Larsen &Toubro Ltd
Interface: HDLC
Authentication: Low
Client Address: 11
Password: Int1
Wait Time: 00:00:05
Resend Count: 3
Address Type: Default
Logical Server: 0
Physical Server: 1
Media: Serial

settings
Serial Port: COM7
Use Maximum Baud Rate 300

Please suggest the proper solution. and let me know where to check the baud rate.

Profile picture for user Kurumi

Kurumi

3 months 3 weeks ago

Hi, You can change the baud…

Hi,

You can change the baud rate from the advanced button. Don't check the "Use maximum baud rate".

You can try with a baud rate of 9600, but you need to check it from the meter documentation or ask the meter vendor.

BR,
Mikko

  • Log in or register to post comments
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

Wed, 09/27/2023 - 13:50
gurux.dlms.c 20230927.1
Fri, 09/22/2023 - 19:50
gurux.dlms.c 20230922.1
Mon, 09/18/2023 - 13:51
Gurux.DLMS.AMI4 4.0.2309.1801
Fri, 09/15/2023 - 12:00
gurux.dlms.c 20230915.1
Tue, 09/12/2023 - 11:10
Gurux.DLMS.AMI4 4.0.2309.1201

Open bugs

gurux.dlms.c
3
gurux.dlms.cpp
3
gurux.dlms.delphi
1
Gurux.DLMS.Net
1

New forum topics

  • Billing Profile Data not getting With Range Selector
  • Unable to Fetch Data using Listener from SMART METER.
  • Not Enough Memory when reading data which does't fit into the max PDU size.
  • DateTime epoch conversion
  • DLMS Client for python
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin