By Gurux Documentation , 10 November, 2026

PRIME physical layer counters

Records corrupted bursts and queue overflows in the PRIME physical layer.

When to use it

For example, distinguish electrical noise from queue overload by comparing CRC errors with dropped data counts.

Attributes

1. Logical name

Identifies this object instance by its six-part OBIS code. Use it to distinguish this object from other objects of the same class.

2. CrcIncorrectCount

Counts received bursts whose CRC integrity check failed.

3. CrcFailedCount

Counts bursts whose CRC passed but whose physical header contained an invalid protocol value, revealing an error missed by the CRC.

4. TxDropCount

Counts occasions when the transmit queue was full and new or queued data had to be discarded.

5. RxDropCount

Counts occasions when the receive queue was full and newly received or queued data had to be discarded.

  • Log in or register to post comments
  • Create new account
  • Reset your password

Book navigation

  • Activity calendar
  • Association Logical Name
  • Auto Connect
  • Auto answer
  • Clock
  • Compact data
  • Data
  • Demand register
  • Disconnect control
  • Extended register
  • GPRS modem setup
  • GSM diagnostic
  • IEC HDLC setup
  • IEC local port setup
  • IPv6 setup
  • Limiter
  • M-Bus Client
  • M-Bus master port setup
  • M-Bus slave port setup
  • MAC address setup
  • Modem configuration
  • PPP setup
  • Profile generic
  • Push Setup
  • Register
  • Register Monitor
  • Register table
  • SAP assignment
  • Script table
  • Security setup
  • Single action schedule
  • Special days table
  • Status mapping
  • Tcp Udp Setup
  • Trasferimento dell'immagine
  • Utility tables
  • Manufacturer custom objects
  • Account
  • Arbitrator
  • Array manager
  • Charge
  • CoAP diagnostics
  • CoAP setup
  • Communication port protection
  • Credit
  • Data protection
  • Function control
  • G3-PLC 6LoWPAN setup
  • G3-PLC MAC layer counters
  • G3-PLC MAC setup
  • LLC SSCS setup
  • LTE monitoring
  • M-Bus diagnostics
  • M-Bus port setup
  • Network time setup
  • Parameter monitor
  • PRIME application identification
  • PRIME MAC counters
  • PRIME MAC functional parameters
  • PRIME MAC setup
  • PRIME network administration data
  • PRIME physical layer counters
  • S-FSK active initiator
  • S-FSK MAC counters
  • S-FSK physical and MAC setup
  • S-FSK reporting system list
  • S-FSK synchronisation timeouts
  • Schedule
  • Short name association
  • STS payment token settings
  • Tariff plan
  • Token gateway
  • Twisted pair setup
  • Wireless mode Q channel
  • IPv4 setup
  • Register activation

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Bank Mandiri KC Tamiang Layang call/wa 0813-627-9539.
  • Bank Mandiri KC Sukamara call/wa 0813-627-9539.
  • Dollar Mart Money Changer ☎️/Wa 083150344509
  • PT.Srikandi Utama Valusindo ☎️/Wa 083150344509
  • Bank Mandiri Kuala Kapuas call/wa 0813-627-9539.
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin