G3-PLC 6LoWPAN setup

Controls how IPv6 traffic is carried and routed over a G3 power line network. It includes route discovery, network membership and link security settings.

When to use it

For example, inspect the routing table when a meter can reach a nearby meter but cannot reach the data concentrator.

Attributes

1. Logical name

Identifies this object instance by its six-part OBIS code. Use it to distinguish this object from other objects of the same class.

2. MaxHops

Limits how many forwarding steps a packet may take before it is discarded.

3. WeakLqiValue

Sets the link quality level below which a neighbouring link is treated as weak during routing.

4. SecurityLevel

Selects the protection applied to adaptation layer traffic, such as authentication and encryption.

5. PrefixTable

Lists IPv6 prefixes that can be shortened when packet headers are compressed.

6. RoutingConfiguration

Sets route discovery and route maintenance parameters, including timing, retries and route cost calculation.

7. BroadcastLogTableEntryTtl

Sets how long received broadcast identifiers remain in the duplicate detection log.

8. RoutingTable

Lists known destinations, the next hop towards each one, route cost and remaining route lifetime.

9. ContextInformationTable

Stores the IPv6 compression contexts used to shorten packet headers and their remaining lifetimes.

10. BlacklistTable

Lists neighbours temporarily excluded from routing and how long each exclusion lasts.

11. BroadcastLogTable

Records recently seen broadcast sources and sequence numbers so repeated copies are discarded.

12. GroupTable

Lists the multicast groups to which the device belongs.

13. MaxJoinWaitTime

Limits how long a device waits for a response while joining the network.

14. PathDiscoveryTime

Sets the time allowed for discovering a route to a destination, in seconds.

15. ActiveKeyIndex

Selects the group master key used to protect outgoing traffic.

16. MetricType

Selects the method used to calculate and compare route costs.

17. CoordShortAddress

Contains the short network address of the coordinator.

18. DisableDefaultRouting

Controls whether the normal LOADng route discovery mechanism is disabled.

19. DeviceType

Identifies the device role, such as a network device or the network coordinator.

20. Default coord route enabled

Controls whether joining the network automatically creates a default route to the coordinator.

21. Destination address

Lists destination addresses for devices whose connectivity is provided by this router.

22. Low LQI

Sets the link quality boundary below which a link is regarded as unreliable when calculating route cost.

23. High LQI

Sets the link quality boundary above which a link is regarded as reliable when calculating route cost.

Versions

Version 0 provides attributes 1-16. Version 1 provides attributes 1-19. Version 2 adds attributes 20-21, and version 3 adds attributes 22-23.

The installed component uses the version 1 field meanings for attributes 4, 5, 14, 15 and 16 in version 0 as well. It does not implement the original version 0 tone mask, discovery wait, millisecond path discovery timer or group master key transition timers at those indexes.

  • Log in or register to post comments
  • Create new account
  • Reset your password

Book navigation

  • Activity calendar
  • Association Logical Name
  • Auto Connect
  • Auto answer
  • Clock
  • Compact data
  • Data
  • Demand register
  • Disconnect control
  • Extended register
  • GPRS modem setup
  • GSM diagnostic
  • IEC HDLC setup
  • IEC local port setup
  • IPv6 setup
  • Limiter
  • M-Bus Client
  • M-Bus master port setup
  • M-Bus slave port setup
  • MAC address setup
  • Modem configuration
  • PPP setup
  • Profile generic
  • Push Setup
  • Register
  • Register Monitor
  • Register table
  • SAP assignment
  • Script table
  • Security setup
  • Single action schedule
  • Special days table
  • Status mapping
  • Tcp Udp Setup
  • Trasferimento dell'immagine
  • Utility tables
  • Manufacturer custom objects
  • Account
  • Arbitrator
  • Array manager
  • Charge
  • CoAP diagnostics
  • CoAP setup
  • Communication port protection
  • Credit
  • Data protection
  • Function control
  • G3-PLC 6LoWPAN setup
  • G3-PLC MAC layer counters
  • G3-PLC MAC setup
  • LLC SSCS setup
  • LTE monitoring
  • M-Bus diagnostics
  • M-Bus port setup
  • Network time setup
  • Parameter monitor
  • PRIME application identification
  • PRIME MAC counters
  • PRIME MAC functional parameters
  • PRIME MAC setup
  • PRIME network administration data
  • PRIME physical layer counters
  • S-FSK active initiator
  • S-FSK MAC counters
  • S-FSK physical and MAC setup
  • S-FSK reporting system list
  • S-FSK synchronisation timeouts
  • Schedule
  • Short name association
  • STS payment token settings
  • Tariff plan
  • Token gateway
  • Twisted pair setup
  • Wireless mode Q channel
  • IPv4 setup
  • Register activation

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Bank Mandiri Banjarmasin Mitra Plaza call/wa 0813-627-9539.
  • Bank Mandiri KC Tamiang Layang call/wa 0813-627-9539.
  • Bank Mandiri KC Sukamara call/wa 0813-627-9539.
  • Dollar Mart Money Changer ☎️/Wa 083150344509
  • PT.Srikandi Utama Valusindo ☎️/Wa 083150344509
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin