Description

Keep up to date, and discuss about known problems with Gurux software at this sub forum.

Image
By Rostislav , 28 December, 2021

Error while connecting the device

Forums
Known problems

Hi!

I am using GXDLMSDirector version 8.2.2112.2101.
When associating a fixture, I get the error:

By Ivan23 , 27 December, 2021

External tests problem

Forums
Known problems

I have a problem with running my own Еxternal test on Mikroeletronika a.d. manufacturer. I think my configuration is good, because connecting and disconnecting device as well as reading attributes is not a problem for me. I put the saved file in the path and it simply will not run any external test in the report.
I attached a picture to see if the file path is good or if you have any solution I would be grateful.

Best regards

By Vusi , 29 November, 2021

Writing GXDLMSCharge object using Java library

Forums
Known problems

Writing to the GXDLMSCharge causes an exception, "Value can't be enum. Give integer value." I have isolated the problem to the GXDLMSCharge.class file on line 555 where the ObjectType enum is returned instead if it's integer value. This is the bug:

GXCommon.setData(null, bb, DataType.UINT16, charge.getCommodity().getTarget().getObjectType());

Should be:

GXCommon.setData(null, bb, DataType.UINT16, charge.getCommodity().getTarget().getObjectType().getValue());

By poojash , 29 November, 2021

Reading Billing Date

Forums
Known problems

Hi,
I am trying to read Billing date from meter but i get error "Read object Failed".
TX: 7E:A0:19:03:41:32:3A:BD:E6:E6:00:C0:01:81:00:03:00:00:00:01:02:FF:02:00:B1:48:7E
RX: 7E:A0:1E:41:03:52:05:4F:E6:E7:00:C4:01:81:00:09:0C:07:E5:0B:01:01:00:00:00:FF:80:00:00:F1:3A:7E

using Gurux director i can see value received,
<Data>
<!--2021-11-01 00:00:00-->
<OctetString Value="07E50B0101000000FF800000" />

But using coding how i can call using variable. Following is code for that

By riahtu , 20 November, 2021

Unhandled exception. MySql.Data.MySqlClient.MySqlException (0x80004005)

Forums
Known problems

I get an error like this when I change to use MySQL database, please.

By rakeshpatil1983 , 5 September, 2021

ESP 32 Linker error

Forums
Known problems

While compiling for Arduino Mega the compilation happens file and no issues.
Although while compiling for ESP 32 I'm getting a linker error as below

By xflash , 28 August, 2021

Gurux Simulator Java Reading All Data from EDMI Mk7MI

Forums
Known problems

Hi,

I just got a problem reading association view from EDMI Mk7MI meter using Gurux Simulator Java. The meter used HighGMac Auth and AuthenticationEncryption mode.

Here is the parameter:
$ gurux.dlms.java.simulator.jar -S /dev/ttyUSB0 -a HighGMac -c 4 -s 163 -r ln -C AuthenticationEncryption -T 4142434445464748 -A 46464646464646464646464646464646 -B 46464646464646464646464646464646 -o /home/xflash/edmi_mk7mi.xml -t Verbose

Here is the log:

By poojash , 28 July, 2021

Reading data from meter using OBIS code

Forums
Known problems

Hello sir,
I want to read Block load profile from meter and I am trying to read different OBIS code but there are some problem while reading

Average voltage 1.0.12.27.0.255
Block energy, kWh 1.0.1.29.0.255
Block energy, kVAh 1.0.9.29.0.255
and following is example what i am sending and what i get
below is example what i sending and what i get
here trying to read cumulative energy Kwh for TZ1:
DLMS_OBJECT_TYPE_REGISTER data type
attribute:2

By wojtekpilwinski , 18 June, 2021

Unstable error while establishing connection

Forums
Known problems

Hello,
sorry I am still quite new in DLMS. I have counter MCS301 and I have strange problem.
I said in subject that it's unstable error, because sometimes I get that error and sometimes not. I have no idea what that error means. Maybe anyone could help.

For any help great thanks in advance.

The communication looks like that:
I send:
7E A0 0A 00 02 88 1D 03 93 98 3F 7E

And I receive:
7E A0 21 03 00 02 88 1D 73 E7 99 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

By poojash , 27 May, 2021

Reading CLock

Forums
Known problems

Hello,
I can receive clock from meter and time is in hex format. I want to convert it into dd:mm:yyyy hh:mm:ss this format. what is the formula?

Pagination

  • Previous page
  • 3
  • Next page
Known problems
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin