By Jimmy , 2 August, 2025

Image Transfer-Data Block Unavailable

Forums
Gurux.DLMS

Hi, Mikko,

By Pablob , 31 July, 2025

ReadWriteDenied on STRING Object

Forums
Gurux DLMS for ANSI C

Hello,

I have a DLMS server running on a 32-bit MCU and a DLMS host also running on a 32-bit MCU, communicating via PLC. Both work correctly: I have created several objects on the server and can successfully connect, get the association view, perform read/write operations, and close the connection properly.

By vadiraj Revankar , 30 July, 2025

Troubleshooting UA Parsing Failures in DLMS/COSEM over Custom USB Serial on Android (No GXMedia)

Forums
Gurux DLMS for Android

I'm building a DLMS/COSEM client on Android using custom USB serial communication (no GXSerial/GXMedia). I send an SNRM request and receive a UA response that starts and ends with 0x7E, but the Gurux Java parser treats it as malformed.

Works:
Genus and Landis+Gyr meters: UA parsed correctly.

Fails:
HPL and L&T meters: UA response appears malformed.

The same configuration (client address, baud rate, etc.) works fine in the Gurux DLMS demo app.

By manoj panchal , 30 July, 2025

Logical name

Forums
Gurux.DLMS

For single metering manufacturing company should same logical device name for all meters or different. as stated in blue book in clause no. 4.1.8.2 that

Each COSEM logical device can be identified by its unique COSEM LDN. The LDN is defined. as a string of up to 16 octets.
i am mentioning example in both way that which one is correct.

condition 1:-

METER METER SR. NO. LOGICAL DEVICE NAME

By vadiraj Revankar , 29 July, 2025

Single Chunk Association Response — pendingReply Empty Without GXMedia

Forums
Gurux DLMS for Android

Hi,

I’m using GXSerial (USB) without GXMedia to read DLMS meter data. During Association Response, I receive all OBIS codes in one large response frame, like this:

By vadiraj Revankar , 29 July, 2025

Association through Bluetooth GuruX

Forums
Gurux DLMS for Java

I have successfully established the Bluetooth connection and completed both the SNRM and AARQ stages. However, during the Association View phase, I'm facing an issue where the full HDLC response is not being received consistently. Despite requesting the maximum MTU size of 517, the response often gets truncated.

For example, sometimes the Association View responses complete up to the 9th continuation request, while at other times, it stops at the 3rd or 4th request, resulting in an incomplete frame and a parsing failure.

By Administrator , 28 July, 2025

GXDLMSDirector 9.0.2507.2801

The following important issues are resolved in this version:
Support added to M-Bus diagnostic object.

By Administrator , 28 July, 2025

Support added to M-Bus diagnostic object.

Project
GXDLMSDirector
Status
Closed (fixed)
Priority
Normal
Category
Support request
By atuldd , 28 July, 2025

Regarding the dlms android project

Forums
Gurux DLMS for Android

i am using gurux android project where not able to connect with the usb prob
prob details given below

man info:Silicon Labs:CP2102
USB to UART bridge controller
chipset:CP21XX
serial:0001
Boud rate:9600
data bits:8
parity :none
stop bits :1

By supritha , 25 July, 2025

DLMS connection issue with SI controller(EFR32xG23B)

Forums
General discussion

Hi,

when I am trying to communicate with the meter, I am facing issue at 7th transmission I am getting error code response from the meter as read write denied.

could you assist with this issue.

Regards
Supritha K P

Pagination

  • First page
  • Previous page
  • …
  • Page 32
  • Page 33
  • Page 34
  • Page 35
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • …
  • Next page
  • Last page
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin