Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Node
By Administrator , 21 September, 2026

Update: Change the "Server to Client challenge do not match" exception to GXDLMSException with AuthenticationFailure.

Project
Gurux.DLMS.Net
Status
Closed (fixed)
Priority
Normal
Category
Feature request
By Administrator , 21 September, 2026

fix: MultipleBlocks issue

Project
Gurux.DLMS.Net
Status
Closed (fixed)
Priority
Normal
Category
Bug report
By Administrator , 21 September, 2026

add: Use GXDLMSInsufficientDataException instead of OutOfMemoryException

Project
Gurux.DLMS.Net
Status
Closed (fixed)
Priority
Normal
Category
Feature request
By Metin Onan , 17 September, 2026

Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)

Forums
Gurux DLMS for ANSI C

Hello,

I have found security (memory-safety) vulnerabilities in GuruxDLMS.c (Gurux DLMS for ANSI C) and would like to report them privately under coordinated disclosure.

Could you please either enable GitHub Private Vulnerability Reporting on the GuruxDLMS.c repository, or provide a private security contact (email)? I will then share full technical details, proof-of-concept reproducers, and suggested fixes privately.

Thank you.

By Prince-2028 , 11 September, 2026

Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects

Forums
DLMSDirector

Hi,
I am working with a DLMS meter that has 16 Class 7 (Profile Generic) OBIS objects.
I am able to read 12 out of the 16 Profile Generic objects successfully. However, when I try to read the remaining Profile Generic objects, I get the following error:
"Insufficient memory to continue the execution of the program."
The same meter and the same Profile Generic objects work correctly in the TALTECH/Renesas GUI, where I can read the data without any error.

By L0uisc_iot , 8 September, 2026

SN ReadResponse returns all-null values when response spans multiple HDLC frames

Forums
Gurux.DLMS

Environment:

- Gurux.DLMS.NET 9.0.2605.2801 (latest release at time of writing), Gurux.Net 8.4.2604.201, .NET 8
- HDLC over TCP, SN (short-name) referencing (UseLogicalNameReferencing = false)
- Landis+Gyr E650, HDLC negotiated MaxInfoTX=128 / MaxInfoRX=62, window size 1

By Sanjaykumar5115 , 3 September, 2026

Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,

Forums
Gurux DLMS for Android

Hi Gurux team,

I am testing an optical probe/cable with Gurux.Serial.Android 3.0.6, which is the latest version I am currently using.

The same USB serial cable works correctly with Gurux.Serial.Java on my computer, but I am unable to get communication working with Gurux.Serial.Android.

Gurux version
Gurux.Serial.Android: 3.0.6
USB-Serial adapter details
Android detects the USB device successfully with the following information:

By Uthuk3l@ , 2 September, 2026

Trying to talk to a L&G E360 meter (Using Python Gurux)

Forums
Gurux DLMS for Python

I'm struggling to communicate with an L&G meter. I can share the code I'm using as well as the logs. I need help.

By andre538 , 1 September, 2026

Reading PushSetupObject attr 10 error

Forums
DLMSDirector

Hello Mikko,

DLMS Director gives me an error message (something like Can't convert GXEnum to GXStructure) while reading Push Setup object.
I've made a little investigation.

By Alex S , 31 August, 2026

addCaptureObject as Class ID=01 (Data) (not 03 (Register))

Forums
Gurux.DLMS

Hi!

I'm successfully writing profile in 0.0.21.0.1.255 (Display profile):

pg = GXDLMSProfileGeneric("0.0.21.0.1.255")

pg.addCaptureObject(GXDLMSRegister("some.obis.code1"),2,0)
pg.addCaptureObject(GXDLMSRegister("some.obis.code2"),2,0)

reader.write(pg,3)

But when i read this profile i see that ClassID is always "03":

7E A0 37 61 02 65 74 E9 8D E6 E7 00 C4 01 C1 00 01 02 02 04 12 00 03 09 06 some.obis.code1 0F 02 12 00 00 02 04 12 00 03 09 06 some.obis.code2 0F 02 12 00 00 [CRC] 7E

Pagination

  • First page
  • Previous page
  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • …
  • Next page
  • Last page
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101
  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202

New forum topics

  • Need RJ45 pin configuration for Saral 300 and Saral 305 Secure meters
  • Query Regarding Class 63 Status Mapping Support in Gurux DLMS Python
  • Inhemeter
  • DLMS Server - Profile Generic - can't add too many items to profile generic capture object - how to set maximum profile entries
  • HDLC Frames sequencing
More
RSS feed
Privacy FAQ GXDN Issues Contact