By rajfanofsachin , 20 July, 2017
Forums
Gurux.DLMS

Hi, with u r support i have successfully downloaded all available objects and association view etc from Indian meter using C++ library. Many thanks for that. It was COM problem in Linux, especially Dialout permission to all users.
Now i wanted to read only specific objects using OBIS codes, eg: 1.0.32.7.0.255. voltage

One more thing, what are things needed along with OBIS codes, like IC, attribute, datatype etc specific to a parameter to read with C++ library?
I have gone through the forum and found some c# codes related codes. Could give me example code for reading only voltage for example in c++.(I am using logical name referencing and OBIS codes)

Thanks.

Profile picture for user Kurumi

Kurumi

9 years 4 months ago

Help needed in reading only wanted objects

Hi,

You can skip read association view and add objects by hand.
Like this:
CGXDLMSRegister* pReg = new CGXDLMSRegister("1.0.32.7.0.255");
Objects.push_back(pReg);
//Read object as usual.
BR,

Mikko

pradson

8 years 11 months ago

Help needed in reading only wanted objects

The above mentioned code is showing this message after running :

Access Error: Device reports undefined object.
Kindly suggest me.

Thanks

Profile picture for user Kurumi

Kurumi

8 years 11 months ago

Help needed in reading only wanted objects

Hi,

I believe that Logical name is wrong. Read meter with GXDLMSDirector first. Also make sure that object type is correct. If you want to read a data object, you must use CGXDLMSData, not CGXDLMSRegister, etc.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Landis E650 meter reading over DLMS
  • class_id = 40, version = 2, pushsetup Unparsed data frame
  • GXObisValueItem entries without MaskSize appear to be interpreted as bit flags
  • CheckedListBox incorrectly selects GXObisValueItem Value=0 for non-zero values
  • UIValueType=TextBox is rendered as CheckedListBox when Values are defined
More

Who's new

  • Sayang
  • q80435762@gmail.com
  • ONCAK
  • Berhasil
  • ratirvivege1979
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin