Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Forums
  3. Help Needed In Reading Only Wanted Objects

Help needed in reading only wanted objects

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By rajfanofsachin , 20 July, 2017
Forums
Gurux.DLMS

Hi, with u r support i have successfully downloaded all available objects and association view etc from Indian meter using C++ library. Many thanks for that. It was COM problem in Linux, especially Dialout permission to all users.
Now i wanted to read only specific objects using OBIS codes, eg: 1.0.32.7.0.255. voltage

One more thing, what are things needed along with OBIS codes, like IC, attribute, datatype etc specific to a parameter to read with C++ library?
I have gone through the forum and found some c# codes related codes. Could give me example code for reading only voltage for example in c++.(I am using logical name referencing and OBIS codes)

Thanks.

Profile picture for user Kurumi

Kurumi

8 years 10 months ago

Help needed in reading only wanted objects

Hi,

You can skip read association view and add objects by hand.
Like this:
CGXDLMSRegister* pReg = new CGXDLMSRegister("1.0.32.7.0.255");
Objects.push_back(pReg);
//Read object as usual.
BR,

Mikko

pradson

8 years 6 months ago

Help needed in reading only wanted objects

The above mentioned code is showing this message after running :

Access Error: Device reports undefined object.
Kindly suggest me.

Thanks

Profile picture for user Kurumi

Kurumi

8 years 6 months ago

Help needed in reading only wanted objects

Hi,

I believe that Logical name is wrong. Read meter with GXDLMSDirector first. Also make sure that object type is correct. If you want to read a data object, you must use CGXDLMSData, not CGXDLMSRegister, etc.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin