Hi,

I have installed DLMSDirector 8.0.1612.2003 and I try to connect to an gas meter by Meter Italia EG4.

It use DLMS protocol with GMAC security level. I have the official tool to test the meter by serial probe.

I have set the parameter in manufacturers to add the new equipment, and when try to connect I obtain this log:
14:14:57 Initializing serial connection.
14:14:57 02:14:57.370 Info Opening
14:14:57 02:14:57.370 Info Serial Port Settings: Port Name: COM3 Baud Rate: 19200 Data Bits: 8 Parity: None Stop Bits: One Eop: None
14:14:57 02:14:57.402 Info Open
14:14:57 Send SNRM request.
7E A0 15 02 21 03 93 B2 09 81 80 08 05 02 01 00 06 02 01 00 56 96 7E
14:14:57 02:14:57.402 Sent 7E A0 15 02 21 03 93 B2 09 81 80 08 05 02 01 00 06 02 01 00 56 96 7E
14:14:57 02:14:57.434 Received 7E A0 21 03 02 21 73 1A
14:14:57 02:14:57.449 Received 1A F7 81 80 14 05 02 01 00 06 02 01 00 07 04 00 00 00 01 08
14:14:57 Received data
7E A0 21 03 02 21 73 1A F7 81 80 14 05 02 01 00 06 02 01 00 07 04 00 00 00 01 08 04 00 00 00 01 69 6D 7E
14:14:57 Parsing UA reply.<CR><LF>81 80 14 05 02 01 00 06 02 01 00 07 04 00 00 00 01 08 04 00 00 00 01
14:14:57 Parsing UA reply succeeded.
14:14:57 Send AARQ request
7E A0 69 02 21 03 10 E2 DD 60 5D A1 09 06 07 60 85 74 05 08 01 03 A6 0A 04 08 34 35 03 84 23 09 04 03 8A 02 07 80 8B 07 60 85 74 05 08 02 02 AC 12 80 10 15 76 33 69 33 2D 43 50 1F 6E 51 4F 2A 24 69 30 BE 23 04 21 21 1F 30 00 00 00 01 44 B7 F8 3D 37 44 A6 4F CE FB 83 7D 27 2F 42 93 05 31 F0 C6 4E 1D C0 54 3D BD 47 B5 7E
14:14:57 02:14:57.449 Sent 7E A0 69 02 21 03 10 E2 DD 60 5D A1 09 06 07 60 85 74 05 08 01 03 A6 0A 04 08 34 35 03 84 23 09 04 03 8A 02 07 80 8B 07 60 85 74 05 08 02 02 AC 12 80 10 15 76 33 69 33 2D 43 50 1F 6E 51 4F 2A 24 69 30 BE 23 04 21 21 1F 30 00 00 00 01 44 B7 F8 3D 37 44 A6 4F CE FB 83 7D 27 2F 42 93 05 31 F0 C6 4E 1D C0 54 3D BD 47 B5 7E
Data send failed. Try to resend 1/3
14:15:07 02:15:07.459 Sent 7E A0 69 02 21 03 10 E2 DD 60 5D A1 09 06 07 60 85 74 05 08 01 03 A6 0A 04 08 34 35 03 84 23 09 04 03 8A 02 07 80 8B 07 60 85 74 05 08 02 02 AC 12 80 10 15 76 33 69 33 2D 43 50 1F 6E 51 4F 2A 24 69 30 BE 23 04 21 21 1F 30 00 00 00 01 44 B7 F8 3D 37 44 A6 4F CE FB 83 7D 27 2F 42 93 05 31 F0 C6 4E 1D C0 54 3D BD 47 B5 7E
14:15:07 02:15:07.522 Received 7E A0 08 03 02 21 97
14:15:07 02:15:07.538 Received 97 C5 67
14:15:07 Received data
7E A0 08 03 02 21 97 C5 67 7E
14:15:07 Parsing AARE reply<CR><LF>
14:15:07 Disconnect request
14:15:07 02:15:07.538 Info Closing
14:15:07 02:15:07.663 Info Closed
System.OutOfMemoryException: Memoria insufficiente per continuare l'esecuzione del programma.
System.OutOfMemoryException: Insufficient Memory.
in GXDLMSDirector.GXDLMSDevice.InitializeConnection()
in GXDLMSDirector.MainForm.Connect(Control sender, Object[] parameters)

Have you any idea? What can do to test and solve the problem?

Thanks in advance

Profile picture for user Kurumi

Kurumi

9 years 5 months ago

Insufficient memory

Hi,

Your meter rejects the command. I believe that reason for this is that your
block chipher key or authentication key is not correct.

Also try to change server and client address to 1.

BR,

Mikko

Hauraky

9 years 5 months ago

Insufficient memory

Hi,
Server and client address are to 1 and server physical to 16 (dec).
Block chipher and authentication key are the same that I'am using with another tool.
In detail I use the same key for both field like in the other tool.

Can I send to you the config print screen and gxc file? To what email address?

Thanks

Profile picture for user Kurumi

Kurumi

9 years 5 months ago

Insufficient memory

Hi,

You find this info from here:
http://www.gurux.fi/AboutUs

We are holiday on next week, but we'll check this in January.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin