Hi

I am trying to connect a ISKRA MT880 via network.

The meter is connected to the net via media converter ethernet -> RS485 and it is accessible via ISKRA software without any problem.

In director I have setup the ip address, password, and the hdml address of the counter. When I try to connect no answer.

I have attached a snapshot of the settings.

Any idea what's could be wrong.

Thanks a lot
Best regards,
gp

Image
Profile picture for user Kurumi

Kurumi

9 years 8 months ago

ISKRA MT880

Hi,

Try to change settings described http://www.gurux.fi/GXDLMSDirectorExample

If that is not working you can send your MeterView trace to me by email and I'll tell what parameters you should use.

BR,

Mikko

gpontaro

9 years 8 months ago

In reply to ISKRA MT880 by Kurumi

Trace

Hi

not sure if you need this ... otherwise please let me know.
Thanks a lot
Best regs
gp

HDLCAddress 74
ProtocolDriver MeterHDLC
PurgeBeforeSend False
SendDelay 0
CommunicationParameters 0
DeviceDriver DlmsDriver
InstanceMapPath IskraemecoIcg
ProtocolParameters 0
ConnectionDriver Network
ConnectUsing Network
ServerIP 192.168.1.105
ServerPort 4001
TimeOut 5000
ActivateBeforeUpgrade True
ClientAddress 1
IEC1107Mode False
InvokeIdAndPriority 64
Password LETTER
ProtocolDriver MeterCOSEMIcg
ReadWithList False
ReadWithListCount 1
ServerAddress 1
SubdriverProtocol 1
UseUnconfirmedServices True

Profile picture for user Kurumi

Kurumi

9 years 7 months ago

ISKRA MT880

Hi,

There is view Log or something like that on the menu. You can see sent and received bytes.
That is what interest me.

I just realized that I do not know is your TCP/IP to serial port converter supporting baud rate changing.
Select "Use serial port through ethernet". That might help.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet