Handling DLMS_ACTION_REQUEST_TYPE_NORMAL for multiple blocks

By bushidik , 13 June, 2024
Forums
Gurux.DLMS

Hello!

I'm using CPP lib for server implementation.
Recently i've found out that if method action request from client contains response, which doesn't fit to the PDU buffer size (~1024) the "MethodRequestNormal" function doesn't create server->m_Transaction = new CGXDLMSLongTransaction object, which will contain remaining data buffer. So I do it myself in the code for MethodRequestNormal:

CGXDLMSLNParameters p(&settings, invokeId, DLMS_COMMAND_METHOD_RESPONSE, 1, NULL, &bb, error, cipheredCommand);
ret = CGXDLMS::GetLNPdu(p, *replyData);

// MY PART
CGXDLMSValueEventCollection arr;
if (bb.GetSize() != bb.GetPosition())
{
if (server->m_Transaction != NULL)
{
delete server->m_Transaction;
server->m_Transaction = NULL;
}
server->m_Transaction = new CGXDLMSLongTransaction(arr, DLMS_COMMAND_METHOD_REQUEST, bb);
}

But I'm not sure, that everything will be working correctly

Please help me with this

Best regards!

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin