By jjduarte , 3 September, 2021
Forums
DLMSDirector

Hello, I have been trying to configure a TOU tariff on my meter trhough Gurux Director, however i have some doubts about how to implement a TOU structure in the meter.

I have create an Activity Calendar, then i have create an script table that contains all the OBIS code related with tariff 1:
1.0.1.8.1.255,1.0.1.8.2.255,1.0.1.8.3.255...

However in the configuration phase of this OBIS I dont really know what means the following parameters

Type:Execute or Write. What is the difference regarding this TOU for those parameters?What can I achieve with one or another?
Index: No idea
Parameter: No idea
Type:Uint16???

In the other hand, i dont know if i have to do something with the register activation. What does means the masks?

Thanks in advanced
Best Regards

Profile picture for user Kurumi

Kurumi

5 years ago

Hi,

Hi,

Script table script will write active_mask. You can try to change active_mask and you will see the correct parameters.

Index:4
Parameter: active_mask
Type:octet-string

BR,
Mikko

jjduarte

5 years ago

In reply to Hi, by Kurumi

Thanks a lot for your help!

Thanks a lot for your help!
So the operation Type must be write or exectute?
However I don't really understand why do I have to select 4 in the index side. What does it means this value?

thanks in advanced

BR

Profile picture for user Kurumi

Kurumi

5 years ago

Hi,

Hi,

#4 is the attribute index that you want to write.
BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
  • dw772
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin