Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Neil Edney , 20 August, 2021
Forums
DLMSDirector

I guess my first question is, is it possible to use DLMSDirector to connect to an Elster A1700 (or AS230)?

I keep getting 'Failed to receive answer from the modem. Check serial port' - although the modem is dialing the number and the modem attached to the meter is answering (from listening in).

Log (with phone number removed):

GXDLMSDirector 8.2.2108.1901
Log created 08:39:30
08:39:43 Initializing Terminal connection.
System.Exception: Failed to receive answer from the modem. Check serial port.
at GXDLMSDirector.GXDLMSCommunicator.InitTerminal()
at GXDLMSDirector.GXDLMSCommunicator.InitializeConnection(Boolean force)
at GXDLMSDirector.GXDLMSDevice.InitializeConnection()
at GXDLMSDirector.MainForm.Connect(Object sender, GXAsyncWork work, Object[] parameters)
08:41:19 Initializing Terminal connection.
08:41:19 08:41:19.758 Info Opening
08:41:19 08:41:19.758 Info Settings: Port: COM6 Baud Rate: 9600 Data Bits: 8 Parity: None Stop Bits: One Eop: None
08:41:19 08:41:19.764 Sent 41 54 45 30 0D 0A
08:41:19 08:41:19.766 Received 0D 0A 4F 4B 0D 0A
08:41:19 08:41:19.767 Sent 41 54 0D
08:41:19 08:41:19.768 Received 0D 0A 4F 4B 0D 0A
08:41:19 08:41:19.769 Sent 41 54 44 xx xx xx xx xx xx xx xx xx xx xx 0D 0A
08:41:49 08:41:49.783 Info Closing
08:41:49 08:41:49.785 Info Closed
System.Exception: Failed to receive answer from the modem. Check serial port.
at GXDLMSDirector.GXDLMSCommunicator.InitTerminal()
at GXDLMSDirector.GXDLMSCommunicator.InitializeConnection(Boolean force)
at GXDLMSDirector.GXDLMSDevice.InitializeConnection()
at GXDLMSDirector.MainForm.Connect(Object sender, GXAsyncWork work, Object[] parameters)

Profile picture for user Kurumi

Kurumi

4 years 11 months ago

Hi,

Hi,

Elster A1700 is using IEC 62056-21, so it's not possible. You can make your own app. You should check this link:
https://www.gurux.fi/node/5415

BR,
Mikko

Neil Edney

4 years 11 months ago

Thanks for the quick reply -

Thanks for the quick reply - had a feeling you'd say that!

Any issue using Gurux.Terminal to aid the development of the app?

Profile picture for user Kurumi

Kurumi

4 years 11 months ago

Hi,

Hi,

I can't remember that we have ever used a terminal connection. We have always read it using serial port.
But there shouldn't be any differences.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200
  • Mon, 06/15/2026 - 08:52
    gurux.dlms.c 9.0.2606.1501

New forum topics

  • Service not known error on gprs communication
  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
More

Who's new

  • ksFhuuipOxKrxk…
  • sherylrk3
  • OLaneHycle
  • LxfgLnoisbruoL…
  • SunbetLith
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin