  3. Gurux Gives Error of "Not Enough Data"

Gurux gives error of "Not Enough data"

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By vivekchitte , 31 July, 2021
Forums
DLMSDirector

When I am connected gurux to my meter using suite 1 High level with ECDSA authentication mechanism it shows a pop-up error message "Not enough data".

please guide me to resolve this error.

thank you.

Profile picture for user Kurumi

Kurumi

5 years 1 month ago

Hi,

Hi,

Can you add sent and received bytes as a hex?

BR,
Mikko

vivekchitte

5 years 1 month ago

Hi Mikko,

Hi Mikko,

please check the below log reply for your reference. this happens when I am trying to connect to the meter.

GXDLMSDirector 8.2.2107.2101
Log created 12:36:01
12:36:04 Initializing Network connection.
12:36:04 Send AARQ request.
00 01 00 30 00 01 00 5F 60 5D A1 09 06 07 60 85 74 05 08 01 03 A6 0A 04 08 31 32 33 34 35 36 37 38 8A 02 07 80 8B 07 60 85 74 05 08 02 07 AC 12 80 10 50 0F 2D 30 05 44 05 64 30 61 5D 48 25 73 4A 27 BE 23 04 21 21 1F 31 00 00 00 00 A5 C9 10 AF E4 9C DC DA F0 CD AA 4E 8B 29 7C BD 0D DE CA 36 78 8A EB 74 9C CC
12:36:04
00 01 00 01 00 30 00 97 61 81 95 A1 09 06 07 60 85 74 05 08 01 03 A2 03 02 01 01 A3 05 A1 03 02 01 01 BE 7B 04 79 28 77 31 00 00 00 02 F7 F2 D6 B5 E7 F7 62 AB EF 07 E1 81 73 DF 11 A3 50 7C 30 81 49 45 B6 63 BB 8D FA 66 DD 55 B2 BB B8 0C 50 DB C4 1B D3 7B 6A 55 34 3A E5 5A 18 83 56 AC 41 66 7D 4B 1A 84 0B 1C F1 21 1F 98 24 8E B2 71 6E 78 B6 5B 4F 0A 16 79 88 86 41 5A 72 46 DD 73 9B FB B8 E7 3D C0 09 CB 16 FE B1 16 91 D5 DC 6A C2 53 1A 87 77 E4 49 AD F4 1A 58 93 13 2A 57 80
System.Exception: Not enough data.
at GXDLMSDirector.GXDLMSCommunicator.InitializeConnection(Boolean force)
at GXDLMSDirector.GXDLMSDevice.InitializeConnection()
at GXDLMSDirector.MainForm.Connect(Object sender, GXAsyncWork work, Object[] parameters)

thank you

Profile picture for user Kurumi

Kurumi

5 years 1 month ago

Hi,

Hi,

One byte is missing from the reply and it's causing this.
61 81 95 //There are only 148 bytes. This must be fixed for the meter.

Meter doesn't accept the connection and returns the PermanentRejected error. Because I don't have the certificates I can't check this.

BR,
Mikko

vivekchitte

5 years 1 month ago

Hi,

Hi,

please check the below-updated log reply for your reference.

GXDLMSDirector 8.2.2107.2101
Log created 12:28:23
12:28:26 Initializing Network connection.
12:28:26 Send AARQ request.
00 01 00 30 00 01 00 5F 60 5D A1 09 06 07 60 85 74 05 08 01 03 A6 0A 04 08 31 32 33 34 35 36 37 38 8A 02 07 80 8B 07 60 85 74 05 08 02 07 AC 12 80 10 61 01 45 5E 08 3C 09 61 0B 12 3E 68 75 6B 37 02 BE 23 04 21 21 1F 31 00 00 00 00 A5 C9 10 AF E4 9C DC DA F0 CD AA 4E 8B 29 7C BD 0D DE CA 36 78 8A EB 74 9C CC
<WRAPPER len="67" >
<TargetAddress Value="30" />
<SourceAddress Value="1" />
<PDU>
<AssociationRequest>
<ApplicationContextName Value="LN_WITH_CIPHERING" />
<CallingAPTitle Value="3132333435363738" />
<SenderACSERequirements Value="1" />
<MechanismName Value="HighECDSA" />
<CallingAuthentication Value="6101455E083C09610B123E68756B3702" />
<glo_InitiateRequest Value="3100000000A5C910AFE49CDCDAF0CDAA4E8B297CBD0DDECA36788AEB749CCC" />
</AssociationRequest>
</PDU>
</WRAPPER>

12:28:26
00 01 00 01 00 30 00 97 61 81 95 A1 09 06 07 60 85 74 05 08 01 03 A2 03 02 01 01 A3 05 A1 03 02 01 01 BE 7B 04 79 28 77 31 00 00 00 03 D6 D7 90 F5 75 7F AA 54 1B BB 69 8C 17 39 35 88 BD 21 84 8C 24 01 E6 D2 D5 E9 56 C3 44 71 B4 BE CE E1 DD 95 0A 45 37 99 DF EA 80 33 69 96 F5 62 C4 B9 CB 67 E4 1B 2F CA CC 49 18 65 0B 58 3F 62 84 33 4E 67 AC DF BD 59 7F 09 40 02 7B 34 22 B6 BE D3 8C A7 36 D7 98 FD 03 6D 8B 47 A9 8E FE E5 3A 0D CD FE E9 73 3D 8B 54 4A 57 51 50 F5 F1 A4 20 98
<WRAPPER len="9F" >
<TargetAddress Value="1" />
<SourceAddress Value="30" />
<PDU>
<AssociationResponse>
<ApplicationContextName Value="LN_WITH_CIPHERING" />
<AssociationResult Value="01" />
<ResultSourceDiagnostic>
<ACSEServiceUser Value="01" />
</ResultSourceDiagnostic>
<glo_InitiateResponse Value="3100000003D6D790F5757FAA541BBB698C17393588BD21848C2401E6D2D5E956C34471B4BECEE1DD950A453799DFEA80336996F562C4B9CB67E41B2FCACC4918650B583F6284334E67ACDFBD597F0940027B3422B6BED38CA736D798FD036D8B47A98EFEE53A0DCDFEE9733D8B544A575150F5F1A42098" />
</AssociationResponse>
</PDU>
</WRAPPER>

System.Exception: Not enough data.
at GXDLMSDirector.GXDLMSCommunicator.InitializeConnection(Boolean force)
at GXDLMSDirector.GXDLMSDevice.InitializeConnection()
at GXDLMSDirector.MainForm.Connect(Object sender, GXAsyncWork work, Object[] parameters)

thank you

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • Anaglyfos Trading CC
  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin