hi folks,

I bought on ebay an ISKRA MT372 just to have a meter to test real communication with GuruxDirector.
The thing is that when the reader answers the AARE I get a permanent reject :

4: 7E A0 39 21 02 23 30 70 EC E6 E7 00 61 2A A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 01 A3 05 A1 03 02 01 0C BE 11 04 0F 08 01 00 06 5F 1F 04 00 00 1C 1D 04 00 00 07 D5 26 7E
<HDLC len="38" >
<TargetAddress Value="10" />
<!-- Logical address:1, Physical address:17 -->
<SourceAddress Value="91" />
<!-- AARE frame. -->
<FrameType Value="30" />
<PDU>
<AssociationResponse>
<ApplicationContextName Value="LN" />
<!-- PermanentRejected -->
<AssociationResult Value="1" />
<ResultSourceDiagnostic>
<!-- AuthenticationMechanismNameReguired -->
<ACSEServiceUser Value="12" />
</ResultSourceDiagnostic>
<InitiateResponse>
<NegotiatedQualityOfService Value="0" />
<NegotiatedDlmsVersionNumber Value="6" />
<NegotiatedConformance>
<ConformanceBit Name="BlockTransferWithGetOrRead" />
<ConformanceBit Name="BlockTransferWithSetOrWrite" />
<ConformanceBit Name="BlockTransferWithAction" />
<ConformanceBit Name="Get" />
<ConformanceBit Name="Set" />
<ConformanceBit Name="SelectiveAccess" />
<ConformanceBit Name="Action" />
</NegotiatedConformance>
<NegotiatedMaxPduSize Value="1024" />
<VaaName Value="7" />
</InitiateResponse>
</AssociationResponse>
</PDU>
</HDLC>

It seems that I need an authentication method to connect to the meter even when I use client address 0x10. Do you know how can I get over this? Is it possible somehow to find out encryption level and key? is it posible to set the meter to factory settings?

Thanks a lot in advance

Profile picture for user Kurumi

Kurumi

5 years 2 months ago

Hi,

Hi,

You can't connect without authentication. Change Authentication level to Low and use password 12345678.

BR,
Mikko

Profile picture for user rafamarca

rafamarca

5 years 2 months ago

Hi Mikko,

Hi Mikko,

Thanks a lot it worked perfectly!! Now I have communication with the meter...
Is this a ISKRA feature or all the meters work in the same way? I thougth you could connect to any meter using the default address 16 (0x10) for the client meaning no security...
It is more than likely that in a near feautre I would have to read other meters from different brnads and if authentication is required It would be very useful to me to have an idea of the different scenarios I could find...

Again thanks a lot for your support!

Profile picture for user Kurumi

Kurumi

5 years 2 months ago

Hi,

Hi,

It depends on how the meter is configured. :( You can usually connect without authentication, but sometimes the metering company wants that you can't connect without authentication.

Meters are very different and the parameters are depending on the meter.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin