  2. Range and Last Entry Will Not Work For Profile Generic Reading

Range and Last entry will not work for Profile Generic reading

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By KhushbuBadheka , 19 February, 2021
Forums
DLMSDirector

Hi Mikko,

I am trying to read Profile entries for Block Load with all options. In which reading by range & All, are working as expected. However, reading by range and last entry reading will not work with the error of "Invalid Data Checksum".

Please do the needful.

Thanks & Regards,

Profile picture for user Kurumi

Kurumi

5 years 3 months ago

Hi,

Hi,

"Invalid Data Checksum" means that the meter is sending an invalid HDLC frame. I can verify it if you add the last frame here.

BR,
Mikko

KhushbuBadheka

5 years 3 months ago

Thanks Mikko,

Thanks Mikko,
TX: 7E A0 2C 03 61 10 BC BE E6 E6 00 D0 1E 30 00 00 00 20 94 9C 78 AE 26 F6 49 C6 EA 08 8A 07 BA B3 F6 F9 3B 1C DE E7 AB 07 F6 B0 59 AB 56 7E
11:17:14 Data send failed. Try to resend 1/3
11:17:19 Data send failed. Try to resend 2/3
11:17:24 Failed to receive reply from the device in given time.
11:17:24 Release request
TX: 7E A0 11 03 61 32 D1 7B E6 E6 00 62 03 80 01 00 BD 9B 7E
11:17:29 Data send failed. Try to resend 1/3
11:17:34 Data send failed. Try to resend 2/3
11:17:39 Failed to receive reply from the device in given time.
11:17:39 Disconnect request
TX: 7E A0 07 03 61 53 65 81 7E
11:17:44 Data send failed. Try to resend 1/3
11:17:49 Data send failed. Try to resend 2/3
11:17:54 Failed to receive reply from the device in given time.

Please find the sent frames.

Profile picture for user Kurumi

Kurumi

5 years 3 months ago

Hi,

Hi,

Is the meter answering at all after this or do you need to boot it?
This seems like a meter issue.

BR,
Mikko

KhushbuBadheka

5 years 3 months ago

Hi Mikko,

Hi Mikko,

The meter is answering after failed for this case.

Thanks & Regards,
Khushbu

Profile picture for user Kurumi

Kurumi

5 years 3 months ago

Hi,

Hi,

There is no "Invalid Data Checksum" error in your trace. When you are receiving it?

BR,
Mikko

KhushbuBadheka

5 years 3 months ago

Hi Mikko,

Hi Mikko,

I found that error on UI only.

Thanks

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin