By dntimmie , 17 September, 2020
Forums
DLMSDirector

I have a EMH LZQJ-XC in combination with the EMH Variomod-XC LTE. I can connect to the meter with their software (Combimaster), but not with Gurux DLMS Director. All setting are OK. Beneath the log if I connect:

07:49:19 07:49:19.756 Info Opening
07:49:19 07:49:19.756 Info Client Settings: Protocol Tcp Host: 188.207.43.244 Port: 8000
07:49:20 07:49:20.346 Info Open
07:49:20 Send SNRM request.
TX: 7E A0 0A 00 02 7E 73 41 93 A9 63 7E
07:49:20 07:49:20.856 Sent 7E A0 0A 00 02 7E 73 41 93 A9 63 7E
07:49:30 Failed to receive reply from the device in given time.
07:49:30 Send Disconnect request.
TX: 7E A0 0A 00 02 7E 73 41 53 A5 A5 7E
07:49:30 07:49:30.870 Sent 7E A0 0A 00 02 7E 73 41 53 A5 A5 7E
07:49:40 Failed to receive reply from the device in given time.
07:49:40 07:49:40.878 Info Closing
07:49:40 07:49:40.878 Info Closed

What could cause the problem?

Image
Profile picture for user Kurumi

Kurumi

6 years 2 months ago

Hi,

Hi,

Change the Logical server from 10 to 0. Is 10077865 serial number of the meter?

BR,
Mikko

dntimmie

6 years 2 months ago

EMH came with the following

EMH came with the following solution: Unselect Create 7E1 parity. I can now connect to the meter and all parameters. Thank you.

Solved.

Profile picture for user Kurumi

Kurumi

6 years 2 months ago

Hi,

Hi,

So you are not using direct TCP/IP connection to the meter. You have Moxa, etc in the middle.
I'm glad that this is solved. Serial port settings might sometimes cause a lot of pain.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Landis E650 meter reading over DLMS
  • class_id = 40, version = 2, pushsetup Unparsed data frame
  • GXObisValueItem entries without MaskSize appear to be interpreted as bit flags
  • CheckedListBox incorrectly selects GXObisValueItem Value=0 for non-zero values
  • UIValueType=TextBox is rendered as CheckedListBox when Values are defined
More

Who's new

  • Sayang
  • q80435762@gmail.com
  • ONCAK
  • Berhasil
  • ratirvivege1979
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin