Hello Mikko,

While testing for profile generic Interface class, I'm facing issue while reading profiles. Initially when default capture objects are present, and I try to read the profile, it read successfully with correct data, and number of profile entries. But when I add capture object from GuruxDlmsDirector, and try to read the profile I'm getting "The number of columns does not match" error dialog box.

Add and remove options in dlms director, are they for viewing purpose only?. Modifying it, doesn't actually add that obis code in profile. Does set operation is nor performed in this case?

Thank you & regards,
Anudeep

Profile picture for user Kurumi

Kurumi

6 years 2 months ago

Hi Anudeep,

Hi Anudeep,

I believe that you need to refresh the object list after you have added the objects. Select profile generic you want to update and then select "Refresh" from "File" menu. It'll update capture objects.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • Anaglyfos Trading CC
  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin