By ramdev3108 , 10 March, 2020
Forums
General discussion

Dear Sir/Madam,
I have couple of doubts while developing the meter server application.
1).What is error response for the "not defined attribute", When i am trying to GET/SET/ACTION on it,
2).My server LLS password is 5 bytes if any one write more than 5 bytes LLS password ,what is the error response the meter has to give.

Regards
DLMS Team

Profile picture for user Kurumi

Kurumi

6 years 4 months ago

Hi,

Hi,

1. You try to read object that don't exists. Check logical name and object type
2. Authentication failed.

BR,
Mikko

ramdev3108

6 years 4 months ago

Thanks for your reply sir,

Thanks for your reply sir,

May be my questioning is not clear to you,

my doubts are,

1).For example my object exists with 2 attributes in the severer , if any client want to GET/SET/ACTION on the third attribute ,what is the error response the meter has to give?.

Because there is no third attribute in my object.

2).My LLS password length is 5-bytes if any tool write more than 5-byte of LLS password after successfully authenticated what is the error response should I give ,because my password length is

5-bytes the new password length is more then 5-bytes.

Profile picture for user Kurumi

Kurumi

6 years 4 months ago

Hi,

Hi,

This is defined in DLMS standard. You can get this information from there.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More

Who's new

  • CTKNhZElptjSlOrpkXl
  • YCbccqfLGRMnlCWoJhXP
  • Malcolmactig
  • mhliang
  • Kevinmug
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin