Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. How To Delete System Title From Get/set Frame

How to delete System Title from get/set frame

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By SgmUsr , 3 October, 2019
Forums
General discussion

Hi all,

I'm using an italian standard meter and our meters don't need system title during get/set request:

(example:
7E A0 36 02 21 03 32 6C C0 E6 E6 00 DB 08 00 00 00 00 00 00 00 00 1E 30 80 00 00 55 0E 89 E1 E4 0C A5 EB BB 00 5C AF D9 A5 F3 B8 B1 E1 7D AF E0 23 37 B9 85 10 71 2C 7E ,
08 00 00 00 00 00 00 00 00 is my system title (08 is the lenght) and if I delete this and set 00 as substitute, I can decrypt this frame correctly.)

There is a method to not add system title?

Thanks

Profile picture for user Kurumi

Kurumi

6 years 8 months ago

Hi,

Hi,

If you set Standard to Italian system title is ignored.
In GXDLMSDirector you can set it on the meter's advanced tab.

GXDLMSSecureClient cl = new GXDLMSSecureClient();
cl.Standard = Standard.Italy;

BR,
Mikko

SgmUsr

6 years 8 months ago

In reply to Hi, by Kurumi

Thank you very much!

Thank you very much!

Now It's work.

Thanks

SgmUsr

6 years 8 months ago

In reply to Hi, by Kurumi

Hi Mr Mikko,

Hi Mr Mikko,

with this change I have another problem:
when I arrive at this point (inside ReadDlmsPacket() method)
//Loop until whole COSEM packet is received.
while (!clientSecured.GetData(p.Reply, reply, new GXReplyData())){ ...}
It always return reply.Error = 4, but I don't understand why, though settings are the same.

Thanks

Profile picture for user Kurumi

Kurumi

6 years 8 months ago

Hi,

Hi,

Because the system title is not coming from the meter you need to set manually.
In GXDLMSDirector select "Pre-established Application Associations" and set the system title of the meter.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin