By Gertschi , 11 February, 2019
Forums
DLMSDirector

Hello!!

I´m trying to read the Landis + Gyr E450. But I don´t know where to set the right parameters.
The meter is connected serial to the Gurux GXDLMSDirector Version 8.1.1901.1601 running on Win10 64Bit.
I got the authentication and the encyrption-key from my gridoperator, but no block cipher key.
Tell me if i´m wrong, but I think the system title are the first 8 symbols of the Meterserial.
In my case it would be: ZMXi320C

A userinterface specification from my gridoperator for the meter could be found here: https://www.netzburgenland.at/fileadmin/NB_pdf_NEU/Smart_Meter/Spezifik…

Hope that someone can help me.

Profile picture for user Kurumi

Kurumi

7 years 9 months ago

Parameters for the Landis + Gyr E450

Hi,

Meter manufacturer defines used system title. With some meters it can be anything as long it's 8 bytes long.
If the length of the encryption-key is 16 bytes, try to set it to the block cipher key.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101
  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202

New forum topics

  • GXObisValueItem entries without MaskSize appear to be interpreted as bit flags
  • CheckedListBox incorrectly selects GXObisValueItem Value=0 for non-zero values
  • UIValueType=TextBox is rendered as CheckedListBox when Values are defined
  • Displaying mapped UInt8 values as read-only text in GXDLMSDirector
  • Python example can't read date from meter using WRAPPER connection
More

Who's new

  • barez fredj
  • MiguelC
  • Hichem Nasraoui
  • Matt_Plumer
  • King Won
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin