  2. Long Reading Ends With "Invalid Frame ..." Error.

Long reading ends with "Invalid frame ..." error.

By abk964 , 16 May, 2025
Forums
Gurux DLMS for ANSI C

Long seances (hundreds of HDLC packets) ended with "Invalid frame..." errors. Same readings in Director are OK. Different devices.

What can I check by myself?

Profile picture for user Kurumi

Kurumi

1 year ago

Hi, If the devices are…

Hi,

If the devices are different, check that they have the same meter firmware.

You didn't tell what you tried to read, but I believe it's a profile generic.

You can usually ignore the Invalid frame error if you read only a few days from the profile generic at a time. So decrease the number of days that you try to read in one sitting.

BR,
Mikko

abk964

1 year ago

Hi. Found my own mistake…

Hi.

Found my own mistake. Thanks.

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin